Improving the signal visibility of optical-disk-drive sensors by analyte patterning and frequency-domain analysis

Abstract: One limitation of using compact disks (CDs) and optical disk drives for sensing and imaging of analytes placed on a CD is the fluctuations in the voltage signal from the disk drive generated while reading the data on the CD. In this study, we develop a simple, low-cost strategy for sensing and identification using CDs and optical disk drives that spectrally separates contributions to the voltage signal caused by an analyte intentionally placed onto the CD and that caused by the underlying data on the CD. Analy… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 13 publications
0
2
0
Order By: Relevance
“…Therefore, by using the intensity of the resulting peak as analytical magnitude, noise can be efficiently discriminated in order to analyze biointeractions in a more sensitive fashion. Schaefer and Chau explored this strategy to discriminate voltage fluctuations in an ink-based optical system [13]. Hereinafter, we introduce for the first time FDA for biochemical analysis, describe and discus the key parameters for its implementation, and experimentally demonstrate the performance improvement provided by this methodology.…”
Section: A C C E P T E D Mmentioning
confidence: 99%
“…Therefore, by using the intensity of the resulting peak as analytical magnitude, noise can be efficiently discriminated in order to analyze biointeractions in a more sensitive fashion. Schaefer and Chau explored this strategy to discriminate voltage fluctuations in an ink-based optical system [13]. Hereinafter, we introduce for the first time FDA for biochemical analysis, describe and discus the key parameters for its implementation, and experimentally demonstrate the performance improvement provided by this methodology.…”
Section: A C C E P T E D Mmentioning
confidence: 99%
“…Optimal focusing of the lens is achieved by fine, micrometerscale adjustments of the vertical and horizontal lens position using the coil actuator. In recent years, there has been increasing interest in using the optical and mechanical components integrated into optical pickup units for imaging and sensing applications [11][12][13][14][15][16]. Here, we adapt an optical pickup unit by replacing the laser diode with an LED and the photodiode with a standard web camera (Logitech Webcam C160) that interfaces with a computer through a USB connection.…”
mentioning