2018
DOI: 10.11591/ijeei.v6i4.473
|View full text |Cite
|
Sign up to set email alerts
|

Improving the Transient Stability of the Mixed AC/DC Networks with FACTS

Abstract: It is probable that future power transmission systems will contain more HVDC-VSC links (High Voltage Direct Current-Voltage Source Converter) leading to a growing complexity in the study of its problem and so do the transient stability problems which are yet to be determined. In this context, this paper presents an efficient method to resolve this problem. Its main objective consists of improving transient stability of the AC/DC (Alternating Current/ Direct Current) power system network using FACTS (Flexible A… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 9 publications
0
3
0
Order By: Relevance
“…Series FACTS controllers are mainly used to compensate for the line reactance and hence to control power transfer in long transmission lines. Series FACTS controllers also enhance the transient stability of a mixed AC / DC system [4]. For economic reasons, it is preferable to use a combination of a fixed series capacitor, and a voltage source controller (VSC) based SSSC [5].…”
Section: Introductionmentioning
confidence: 99%
“…Series FACTS controllers are mainly used to compensate for the line reactance and hence to control power transfer in long transmission lines. Series FACTS controllers also enhance the transient stability of a mixed AC / DC system [4]. For economic reasons, it is preferable to use a combination of a fixed series capacitor, and a voltage source controller (VSC) based SSSC [5].…”
Section: Introductionmentioning
confidence: 99%
“…The voltage must remains within an authorized range at any point in the network, in all foreseeable production and consumption situations. The proposed goal for this work is to find solution for load shedding [4][5][6][7][8][9]. In this case we proposed an analysis for both the current and projected production system.…”
Section: Introductionmentioning
confidence: 99%
“…The theory of TSC-OPF is an extension of the standard OPF problem to include supplementary constraints for imaginable credible contingencies cases. In a standard form, the OPF problem is defined as in [20][21][22]:…”
mentioning
confidence: 99%