2016
DOI: 10.1016/j.jpba.2016.08.035
|View full text |Cite
|
Sign up to set email alerts
|

Impurity profiling of l-asparagine monohydrate by ion pair chromatography applying low wavelength UV detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 19 publications
0
4
0
Order By: Relevance
“…A cation exchange column [ 28 ], reverse-phase column [ 29 , 30 , 31 , 32 ], hydrophilic interaction liquid chromatography (HILIC)-mode column [ 33 , 34 ], and mix-mode column [ 35 ] are used for HPLC separation. In addition, ion-pair mobile phases are applied to detect amino acid impurities with a reverse-phase column [ 36 , 37 , 38 , 39 ] or HILIC-mode column [ 40 ]. Most amino acids and impurities that lack a chromophore are detected by ultraviolet (UV) detection at a low wavelength near UV 210 nm [ 3 , 29 , 30 , 33 , 36 ] or charged aerosol detection (CAD) [ 29 , 37 , 38 , 39 , 40 ].…”
Section: Analytical Methods To Determine Impurities In Amino Acidsmentioning
confidence: 99%
See 2 more Smart Citations
“…A cation exchange column [ 28 ], reverse-phase column [ 29 , 30 , 31 , 32 ], hydrophilic interaction liquid chromatography (HILIC)-mode column [ 33 , 34 ], and mix-mode column [ 35 ] are used for HPLC separation. In addition, ion-pair mobile phases are applied to detect amino acid impurities with a reverse-phase column [ 36 , 37 , 38 , 39 ] or HILIC-mode column [ 40 ]. Most amino acids and impurities that lack a chromophore are detected by ultraviolet (UV) detection at a low wavelength near UV 210 nm [ 3 , 29 , 30 , 33 , 36 ] or charged aerosol detection (CAD) [ 29 , 37 , 38 , 39 , 40 ].…”
Section: Analytical Methods To Determine Impurities In Amino Acidsmentioning
confidence: 99%
“…In addition, ion-pair mobile phases are applied to detect amino acid impurities with a reverse-phase column [ 36 , 37 , 38 , 39 ] or HILIC-mode column [ 40 ]. Most amino acids and impurities that lack a chromophore are detected by ultraviolet (UV) detection at a low wavelength near UV 210 nm [ 3 , 29 , 30 , 33 , 36 ] or charged aerosol detection (CAD) [ 29 , 37 , 38 , 39 , 40 ]. For more sensitive detection, pre-column derivatization with fluorescence reagents and fluorescence detection (FL) are used.…”
Section: Analytical Methods To Determine Impurities In Amino Acidsmentioning
confidence: 99%
See 1 more Smart Citation
“…Over the last decades, some efforts have been made to develop methods for determining L-Asp in serum samples. Standard instrumental techniques such as ion-pair chromatography [2], spectrophotometry [3], and colorimetric assay [4] have been used for the determination of L-Asp; however, these methods are often sophisticated, time-consuming, and very expensive.…”
Section: Introductionmentioning
confidence: 99%