2010
DOI: 10.1021/ac1027098
|View full text |Cite
|
Sign up to set email alerts
|

In-Capillary Screening of Matrix Metalloproteinase Inhibitors by Electrophoretically Mediated Microanalysis with Fluorescence Detection

Abstract: A capillary electrophoresis-based method with enzymatic reaction inside the capillary for the screening of matrix metalloproteinase (MMP) inhibitors has been developed. MMP-2 and MMP-9, which have been considered as promising targets for cancer therapy, were selected as the model enzymes. The hydrolysis of a fluorogenic substrate catalyzed by MMPs was determined by measuring the increase in fluorescence. For high-throughput screening, the short-end injection was employed. The enzyme, substrate containing inhib… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
29
1

Year Published

2011
2011
2018
2018

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 47 publications
(30 citation statements)
references
References 39 publications
0
29
1
Order By: Relevance
“…However, mixing more than two reactants by EMMA is difficult [8,25,26,28]. In this work, even when combining EMMA to a zero potential amplification step [8,9,26,27] the ADP produced was below the LOQ (about 0.20 M).…”
Section: Preliminary Study Of In-capillary Mixingmentioning
confidence: 68%
“…However, mixing more than two reactants by EMMA is difficult [8,25,26,28]. In this work, even when combining EMMA to a zero potential amplification step [8,9,26,27] the ADP produced was below the LOQ (about 0.20 M).…”
Section: Preliminary Study Of In-capillary Mixingmentioning
confidence: 68%
“…An alternative for sensitive assays is the use fluorescence-labeled substrates in combination with laser-induced fluorescence (LIF) detection [22][23][24][25][26][27]. When using substrates without UV chromophores, derivatization of the products and/or substrates can be performed.…”
Section: Pre-capillary Enzyme Assaysmentioning
confidence: 99%
“…Enzyme kinetic data and the IC 50 value of the argatroban obtained by the EMMA assay were in good agreement with the respective data obtained by a pre-capillary as well as a spectrophotometric assay. Rapid polarity switching for plug mixing was also used in a fluorometric EMMA assay for matrix metalloproteinase (MMP) inhibitors [24]. The substrate was a heptapeptide containing methoxycoumarin as fluorophore and a dinitrophenyl group as quencher.…”
Section: In-capillary Enzyme Assaysmentioning
confidence: 99%
See 1 more Smart Citation
“…The separation and detection of specific substrate peptide and product peptide could be achieved by CE-based method [28,29]. Moreover, CEbased screening method has several other advantages, such as minute requirement of reagents and test compounds, automation, and short analysis time [30][31][32][33]. To date, several CE methods have been reported for studying kinase inhibition or screening of kinase inhibitors [14,21,[34][35][36].…”
Section: Introductionmentioning
confidence: 99%