2010
DOI: 10.1016/j.chroma.2009.12.028
|View full text |Cite
|
Sign up to set email alerts
|

In-line coupling headspace liquid-phase microextraction with capillary electrophoresis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
13
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(13 citation statements)
references
References 38 publications
0
13
0
Order By: Relevance
“…The theoretical optimum ratio between the donor and HS volumes in HS extraction can be obtained by differentiating the equilibrium EF in Eq. with V d , which leads to V d = V h . In order to find the optimum volume of the donor for our study, we compared the peak heights of the analytes as the donor volume was changed from 0.5 to 1.2 mL with the extraction temperature and time fixed at 60°C and 30 min, respectively.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The theoretical optimum ratio between the donor and HS volumes in HS extraction can be obtained by differentiating the equilibrium EF in Eq. with V d , which leads to V d = V h . In order to find the optimum volume of the donor for our study, we compared the peak heights of the analytes as the donor volume was changed from 0.5 to 1.2 mL with the extraction temperature and time fixed at 60°C and 30 min, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…In previous reports of HS‐SDME, highly alkaline acceptor phases were used . However, due to the pH range of 4–10 allowed for a μSIL‐FC‐coated capillary, we used the run buffer of pH 9.2 (without FC‐PN) for the acceptor drop, which also had the benefit of simplifying the overall process.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In this case, the hanging drop is not submerged into the sample solution, but suspended in the headspace of a vial containing the donor phase. This procedure has been applied to the determination of phenols in tap water samples . In this case, an alkaline aqueous drop in the tip of the capillary was suspended into the headspace of a vial containing the water sample.…”
Section: Online Microextraction Cementioning
confidence: 99%
“…Recently, in-line coupling of headspace liquid-phase microextraction with CE was reported for determining volatile species in liquid samples. 8 Although the method has an enrichment factor of several hundred, the procedures were complex and not easy to control. Especially cleaning excessive drops by the filter paper 8 increased contamination possibilities.…”
Section: Introductionmentioning
confidence: 99%