2016
DOI: 10.1007/s11340-016-0197-3
|View full text |Cite
|
Sign up to set email alerts
|

In Situ Laboratory-Based Transmission X-Ray Microscopy and Tomography of Material Deformation at the Nanoscale

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
34
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 49 publications
(34 citation statements)
references
References 59 publications
0
34
0
Order By: Relevance
“…The typical resolution is of the order of 1 to 10 µm per voxel for micro-CT. Therefore x-ray microtomography is sometimes referred to as x-ray microscopy [55,177].…”
Section: Tomography and Laminographymentioning
confidence: 99%
See 1 more Smart Citation
“…The typical resolution is of the order of 1 to 10 µm per voxel for micro-CT. Therefore x-ray microtomography is sometimes referred to as x-ray microscopy [55,177].…”
Section: Tomography and Laminographymentioning
confidence: 99%
“…Very recently, nanotomography was used to image mechanical tests in lab tomographs or synchrotron facilities. In particular, ex-situ [161] and in-situ [177] indentation tests were analyzed.…”
Section: In-situ Testsmentioning
confidence: 99%
“…This study looks at the interplay between crack initiation, microfracture and plastic deformation in relation to the local microstructure, namely the tubules and collagen fibers using in situ 3D X-ray nano-CT indentation. In order to examine the effect of tubule orientation samples are indented using a customised nano-mechanical test rig [54] in three different orientations (0°, 45°and 70°to the long axis of the tubules). Our aim is to develop a better understanding of the crack-tip behaviour in relation to the dentin microstructure during the early stages of crack growth.…”
Section: Introductionmentioning
confidence: 99%
“…X-ray microtomography has been applied both at synchrotron sources (Babout et al, 2006;Connolly et al, 2006) and using laboratory systems (Burnett et al, 2015) to study corrosion processes over time at the micrometre scale. Recently, it has become possible to undertake time-lapse imaging of regions of interest around 50 µm in dimension at resolutions of ß50 nm or better using laboratory nano-CT systems (Patterson et al, 2016). However, to date very little work (Krebs et al, 2015) has exploited laboratory-based x-ray nano-CT for studying the corrosion and protection of metallic materials.…”
Section: Introductionmentioning
confidence: 99%