In-situ LIBS and NRA deuterium retention study in porous W-O and compact W coatings loaded by Magnum-PSI

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 15 publications
(13 citation statements)
references
References 38 publications
0
13
0
Order By: Relevance
“…A simple but still accurate semi-empirical calibration model, similar to the MIEY approximation in GDOES, does not exist in LIBS, because of the much more complex physics involved in the atomization (ablation) and excitation processes. There have been attempts to interpret the LIBS spectra on the basis of the concepts of fundamental plasma physics, using plasma parameters such as excitation temperatures (calibration-free (CF) LIBS [59][60][61]). Their analytical outcome, however, has so far been rather semi-quantitative, with few exceptions, such as the analysis of glass [62].…”
Section: Laser-induced Breakdown Spectrometry (Libs)mentioning
confidence: 99%
“…A simple but still accurate semi-empirical calibration model, similar to the MIEY approximation in GDOES, does not exist in LIBS, because of the much more complex physics involved in the atomization (ablation) and excitation processes. There have been attempts to interpret the LIBS spectra on the basis of the concepts of fundamental plasma physics, using plasma parameters such as excitation temperatures (calibration-free (CF) LIBS [59][60][61]). Their analytical outcome, however, has so far been rather semi-quantitative, with few exceptions, such as the analysis of glass [62].…”
Section: Laser-induced Breakdown Spectrometry (Libs)mentioning
confidence: 99%
“…7 and 8) [37,38]. Similar outgassing experiments were carried out with SP-LIBS (at 1 mbar Ar pressure) in Magnum-PSI [39]. Two hours after (D) plasma switch-off LIBS measurements could be performed.…”
Section: System Sensitivitymentioning
confidence: 99%
“…Ablation rate /laser fluence 60-160 nm/pulse (W) 7 J/cm 2 [54] 400-800 nm/pulse (porous W-Al) 7 J/cm 2 [54] 250-500 nm/pulse (columnar W-O) 15-20 J/cm 2 [39,55] 210 nm/pulse (W-N-D) 66 J/cm 2 [28] Operational press. range H isotope distinguishability 1 bar N2 or air [28] Quality: high till 100 mbar N2 [23] At 1 bar Ar [22] Distinguishable at long delays with low S/N ratio Highest operational press.…”
Section: Table 1 Sp-libsmentioning
confidence: 99%
See 1 more Smart Citation
“…14 Currently, most of the reports on CF-LIBS were performed in open air or reduced pressure at tenths of mbar to 1 bar. 15–18 This type of environment is conducive to obtaining strong LIBS signals. The ambient gas provides collisional excitation to all plume species, and hence, it enhances the signal intensity from all emission lines.…”
Section: Introductionmentioning
confidence: 99%