2014
DOI: 10.1016/j.ijhydene.2014.08.010
|View full text |Cite
|
Sign up to set email alerts
|

In situ measurement of relative humidity in a PEM fuel cell using fibre Bragg grating sensors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(6 citation statements)
references
References 25 publications
0
6
0
Order By: Relevance
“…As a result, the nitrogen crossover coefficient was obtained. David et al [109] mentioned that gas chromatography was used by various other authors to determine the water vapour inside the cell.…”
Section: Gas Chromatographymentioning
confidence: 99%
“…As a result, the nitrogen crossover coefficient was obtained. David et al [109] mentioned that gas chromatography was used by various other authors to determine the water vapour inside the cell.…”
Section: Gas Chromatographymentioning
confidence: 99%
“…The in-lab developed physical sensors can be classified as insertion models and embedment models. The insertion models, which are inserted into PEMFC from fuel inlet and outlet channels of bipolar flow plate, are always based on the optical fiber technique, for example, Fiber Bragg Grating (FBG) based sensors [59,60]. Pei et al [63], Ali et al [68], and Tang et al [69] also developed novel thermocouples to study thermal distributions within fuel cell stacks.…”
Section: Commercialized Liquid Mass Flow M Etermentioning
confidence: 99%
“…G. Hinds et al (12) investigated humidity measurement in the anode and the cathode channel by using commercial sensors. N. David et al (13) measured the relative humidity (RH) at the rib and the channel with the fiber Bragg grating (FBG) sensor. K. Nishida et al (15) quantitatively evaluated the water vapor distribution along the anode flow channel by the humidity test paper.…”
Section: Introductionmentioning
confidence: 99%
“…Lee et al (17) conducted insitu temperature, humidity, current and flow measurements simultaneously with developing micro sensors of 40 µm thickness, although these sensors were too thick to insert between PEMFC materials. These humidity measurements (12)(13)(14)(15)(16)(17)(18)(19) were only conducted in the channel or the GDL/separator interface. J. Gazzarri et al (20) estimated RH on the cathode CL based on impedance methods under different experimental conditions, however, the measurement results were only average humidity value on the cathode CL.…”
Section: Introductionmentioning
confidence: 99%