2022
DOI: 10.1016/j.microrel.2022.114487
|View full text |Cite
|
Sign up to set email alerts
|

In-situ temperature-dependent characterization of copper through glass via (TGV)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(5 citation statements)
references
References 16 publications
0
5
0
Order By: Relevance
“…In a typical example, 2D-DIC is used to measure the surface thermal deformation of metal specimens. 18,19 In most cases, the heating device cannot be built together with the DIC measurement system. Therefore, the specimen can be heated to a certain temperature in the heating device and then placed back in the shooting position to record the deformation image (target image).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In a typical example, 2D-DIC is used to measure the surface thermal deformation of metal specimens. 18,19 In most cases, the heating device cannot be built together with the DIC measurement system. Therefore, the specimen can be heated to a certain temperature in the heating device and then placed back in the shooting position to record the deformation image (target image).…”
Section: Introductionmentioning
confidence: 99%
“…When 2D-DIC is used to measure the deformation of the specimen under a special load, the specimen must face the reposition problem in the ex-situ state before and after the load. In a typical example, 2D-DIC is used to measure the surface thermal deformation of metal specimens 18 , 19 . In most cases, the heating device cannot be built together with the DIC measurement system.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, the failure mechanism and optimization rule of TGV interposer architecture were systemically investigated [ 11 , 12 , 13 , 14 , 15 , 16 , 17 , 18 , 19 ]. Tensile radial and circumferential stresses were attributed to the origin of the circumferential cracks and the formation of radial cracks, respectively [ 11 , 13 , 14 ].…”
Section: Introductionmentioning
confidence: 99%
“…Tensile radial and circumferential stresses were attributed to the origin of the circumferential cracks and the formation of radial cracks, respectively [11,13,14]. Different annealing procedures were designed to study their influence on Cu protrusion mechanisms [12,15], and Cu protrusion was observed to saturate after a dwell time of 4 h with an annealing temperature of 400 • C. Irreversible Cu protrusion of Cu-filled TGV was generated after thermal cycling loading and is attributed to the plastic deformation and creep mechanism of Cu [16]. Different layout designs, such as fully filled via and conformal via, were demonstrated and investigated in terms of their thermomechanical reliability [17].…”
Section: Introductionmentioning
confidence: 99%
“…A specific failure of radial and circumferential cracks has been separately observed and attributed to the stress buildup during the heating and cooling process in the annealing heat treatment procedure [ 12 , 13 ]. The critical stress location of Cu-filled TGV has been explored as a Cu/glass interface because the mismatching of the aforementioned material CTE, the slower ramp rate, and the decent dwell time can help manage the thermal stress [ 14 , 15 ]. To reduce Cu protrusion-induced stress, a conformal-type TGV has been demonstrated, and a fully-filled TGV with considerable copper protrusion during thermal cycling was revealed [ 16 ].…”
Section: Introductionmentioning
confidence: 99%