2019
DOI: 10.1016/j.flowmeasinst.2019.04.004
|View full text |Cite
|
Sign up to set email alerts
|

In-situ water level measurement using NIR-imaging video camera

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
48
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 63 publications
(48 citation statements)
references
References 19 publications
0
48
0
Order By: Relevance
“…However, the numerical solution as Θ is computationally expensive including assumptions for the hydrology process in flood. There is an enormous demand for parameter tuning of the numerical solution Θ once with high-resolution two-dimensional water level measurements mentioned in [36].…”
Section: Numerical Flood Simulation Model and Landlabmentioning
confidence: 99%
“…However, the numerical solution as Θ is computationally expensive including assumptions for the hydrology process in flood. There is an enormous demand for parameter tuning of the numerical solution Θ once with high-resolution two-dimensional water level measurements mentioned in [36].…”
Section: Numerical Flood Simulation Model and Landlabmentioning
confidence: 99%
“…A set of wind-solar hybrid power supply is adopted to keep the measurement system continuously running for at least 7 days. See Reference [36] for details.…”
Section: Measurement Site and Systemmentioning
confidence: 99%
“…Next the orthophoto correction image is binarized, and the gray value of each row of pixels is accumulated to obtain the horizontal projection curve. By searching the abrupt change value in the horizontal projection curve, the water line between water gauge and water surface is determined, and then the water level is obtained [36]. This idea of water-level measurement is a two-step process: one detecting the water level on a pixel space, and two translate these in real world coordinates.…”
Section: Water-level Measurementmentioning
confidence: 99%
See 1 more Smart Citation
“…The latter often involves the manual thresholding of several initial images, and the same approach can then be applied automatically to subsequent images. Optical noise can also be reduced using advanced mathematical algorithms (e.g., [71,72]). However, for NAPL-related investigations, this may cause information loss, especially for image areas with residual NAPL volumes (e.g., ganglia or blobs).…”
Section: Conceptualization Of a Basic Ipa Framework For Dnapl Releasementioning
confidence: 99%