2020
DOI: 10.1016/j.bioelechem.2020.107528
|View full text |Cite
|
Sign up to set email alerts
|

In vitro attenuation of astrocyte activation and neuroinflammation through ibuprofen-doping of poly(3,4-ethylenedioxypyrrole) formulations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 45 publications
0
5
0
Order By: Relevance
“…Capacitance was calculated based on the parameters of a constant phase element (CPE) as described previously. 42 CV curves were used to determine charge storage capacity (CSC) as described previously. 43 Transport properties of ITO/PET were evaluated with the use of a standard four-probe sensing method through the combination of a Keithley 220 current source and two Keithley 6512 electrometers.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Capacitance was calculated based on the parameters of a constant phase element (CPE) as described previously. 42 CV curves were used to determine charge storage capacity (CSC) as described previously. 43 Transport properties of ITO/PET were evaluated with the use of a standard four-probe sensing method through the combination of a Keithley 220 current source and two Keithley 6512 electrometers.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
“…EIS Spectrum Analyzer 1.0 software and the Powell algorithm were used to fit the experimental data to an equivalent circuit model. Capacitance was calculated based on the parameters of a constant phase element (CPE) as described previously . CV curves were used to determine charge storage capacity (CSC) as described previously …”
Section: Materials and Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…These devices have been extensively reviewed elsewhere 42 45 and have been utilized in a variety of recent in vitro neuromodulation demonstrations. 46 52 However, such controlled delivery electrodes have seen few neuromodulation demonstrations in vivo .…”
Section: Chemical Stimulation and Drug Deliverymentioning
confidence: 99%
“…Over the decades, a variety of such controlled delivery electrodes have been demonstrated, all following the basic recipe of embedding bioactive substances in the redox-active conducting polymer film (as counterions in the PPy example above, or co-ions compensating the counterions) and releasing them into the adjacent electrolyte upon redox switching (Figure a). These devices have been extensively reviewed elsewhere and have been utilized in a variety of recent in vitro neuromodulation demonstrations. However, such controlled delivery electrodes have seen few neuromodulation demonstrations in vivo .…”
Section: Chemical Stimulation and Drug Deliverymentioning
confidence: 99%