2021
DOI: 10.1007/978-1-0716-1795-3_9
|View full text |Cite
|
Sign up to set email alerts
|

In Vivo Monitoring of Cytosolic pH Using the Ratiometric pH Sensor pHluorin

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
1

Relationship

3
1

Authors

Journals

citations
Cited by 4 publications
(8 citation statements)
references
References 19 publications
0
8
0
Order By: Relevance
“…The H + -ATPase activity of Pma1 in F. oxysporum was measured in the plasma membrane fraction of germlings as previously described [35] with minor modifications [36] by reading absorbance at 750 nm in a spectrofluorometer (Infinite M200 PRO, TECAN Life Sciences, 8708 Männedorf, Switzerland). Specific Pma1 H + -ATPase activity was calculated by subtracting the residual activity obtained after the addition of the specific Pma1 inhibitor DES, from the total activity (addition of methanol), expressed in mmol/min/g protein and normalized to time zero.…”
Section: Measurement Of Pma1 H + -Atpase Activitymentioning
confidence: 99%
See 4 more Smart Citations
“…The H + -ATPase activity of Pma1 in F. oxysporum was measured in the plasma membrane fraction of germlings as previously described [35] with minor modifications [36] by reading absorbance at 750 nm in a spectrofluorometer (Infinite M200 PRO, TECAN Life Sciences, 8708 Männedorf, Switzerland). Specific Pma1 H + -ATPase activity was calculated by subtracting the residual activity obtained after the addition of the specific Pma1 inhibitor DES, from the total activity (addition of methanol), expressed in mmol/min/g protein and normalized to time zero.…”
Section: Measurement Of Pma1 H + -Atpase Activitymentioning
confidence: 99%
“…Measurements of pH c in F. oxysporum germlings were performed, as previously described [36], by reading fluorescence emission at 510 nm after excitation at 395 nm and 475 nm in a TECAN spectrofluorometer (Infinite M200 PRO, TECAN Life Sciences, Männedorf, Switzerland). The values of the pHluorin-negative wt background were subtracted for each wavelength, and the 395/475 nm ratio was calculated and converted to pH c values using a pH calibration curve [36]. Experiments were performed at least twice with three independent replicate wells each.…”
Section: Cytosolic Ph Measurements Using the Ratiometric Fluorescent ...mentioning
confidence: 99%
See 3 more Smart Citations