2021
DOI: 10.1016/j.talanta.2020.122045
|View full text |Cite
|
Sign up to set email alerts
|

in vivo Monitoring with micro-implantable hypoxia sensor based on tissue acidosis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 41 publications
0
7
0
Order By: Relevance
“…The developed pH ion-selective solid-based micro-sensor exhibited a stable near Nernstian response of − 50 mV/pH unit when used in physiological range of pH 6.8-7.5. The pH calibration plot also demonstrated a wide working linear range, maintaining sensitivity in a broad pH range from 4 to 9 [ 8 ] (Fig. 2 ).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The developed pH ion-selective solid-based micro-sensor exhibited a stable near Nernstian response of − 50 mV/pH unit when used in physiological range of pH 6.8-7.5. The pH calibration plot also demonstrated a wide working linear range, maintaining sensitivity in a broad pH range from 4 to 9 [ 8 ] (Fig. 2 ).…”
Section: Resultsmentioning
confidence: 99%
“…PREs was constructed by immersing the tip of the Ag wire (anode) and a corresponding Pt or Ag wire (cathode) in 3 M KCl for 2 min using 9 V battery, which resulted in the formation of Ag/AgCl layer. The PREs were then coated with Nafion® and cured at 100 °C for 1 h. Both electrodes were inserted within a piece of 5 mm PEEK tubing and stored under argon [ 8 ]..…”
Section: Methodsmentioning
confidence: 99%
“…The sensors used in this article were developed and optimized in previous work [13,14]. In previously reported articles, the sensitivity, specificity, reproducibility, and response time of these sensors are described, which were validated in adult rabbits.…”
Section: Miniaturized Electrochemical Sensors: Ph and Pomentioning
confidence: 99%
“…For that reason, the insulating layer of one end of the metallic wires (Pt or Ag, 15 cm in length and 125 µm in diameter) was carefully removed to solder it with a copper wire (1 m in length). Once the microsoldered section had been isolated, the modifications for preparing the working and the reference electrodes for both types of electrochemical sensor were performed as previously described [13,14]. After the sensors were individually functionalized, they were integrated into a biocompatible tube with a final diameter of 500 µm (See supporting information Figure S1).…”
Section: Miniaturized Electrochemical Sensors: Ph and Pomentioning
confidence: 99%
See 1 more Smart Citation