2007
DOI: 10.1016/j.arth.2006.07.006
|View full text |Cite
|
Sign up to set email alerts
|

In Vivo Oxidation of γ-Barrier–Sterilized Ultra–High-Molecular-Weight Polyethylene Bearings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

6
112
0

Year Published

2008
2008
2015
2015

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 105 publications
(118 citation statements)
references
References 13 publications
6
112
0
Order By: Relevance
“…Moderate oxidation (average OI [ 1) was evident at the rim in annealed and gamma inert liners, but over half of the retrieved annealed liners exhibited severe rim oxidation (average OI [ 3). Previous studies have suggested an ASTM OI exceeding 3 is the critical level at which the mechanical properties are reduced severely enough that the material's ability to withstand repeated loading is diminished [8,17,19]. The rims of acetabular components do not necessarily undergo repetitive mechanical loading throughout the duration of implantation.…”
Section: Discussionmentioning
confidence: 96%
See 3 more Smart Citations
“…Moderate oxidation (average OI [ 1) was evident at the rim in annealed and gamma inert liners, but over half of the retrieved annealed liners exhibited severe rim oxidation (average OI [ 3). Previous studies have suggested an ASTM OI exceeding 3 is the critical level at which the mechanical properties are reduced severely enough that the material's ability to withstand repeated loading is diminished [8,17,19]. The rims of acetabular components do not necessarily undergo repetitive mechanical loading throughout the duration of implantation.…”
Section: Discussionmentioning
confidence: 96%
“…The maximum oxidation index (OI) was calculated from the infrared spectra as the area ratio between the carbonyl peak centered at 1715 cm À1 and the reference band at 1370 cm À1 . Previous studies have suggested an ASTM OI exceeding 3 is the critical level, above which the mechanical properties are reduced and severely compromised [8,17,19]. An OI of less than 1 on the ASTM scale is associated with low oxidation and negligible impact on mechanical behavior.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Ultrahigh-molecular-weight polyethylene (UHMWPE) materials that have been exposed to high-energy ionizing radiation such as gamma or e-beam have been reported to be susceptible to oxidative degradation both in vivo as well as on the shelf [5,10,21,23]. To address this vulnerability, UHMWPE materials have been stabilized by thermal means with varying success [6,11,13,27].…”
Section: Introductionmentioning
confidence: 99%