2012
DOI: 10.1016/j.jjcc.2012.07.011
|View full text |Cite
|
Sign up to set email alerts
|

Incidence and clinical impact of fracture of drug-eluting stents widely used in current clinical practice: Comparison with initial platform of sirolimus-eluting stent

Abstract: Although implantation of the newer DES platforms might reduce the occurrence of SF compared with the CBX, SF-related binary restenosis and TLR remain similarly high. And to predict SF in the newer DES platforms' era, lesion characteristics on index procedure are more important than implanted stent design.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

7
14
0

Year Published

2014
2014
2017
2017

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(21 citation statements)
references
References 15 publications
7
14
0
Order By: Relevance
“…Similarly, the most common modality of presentation for SF cases in either first generation or contemporary platforms in our analysis was in‐stent restenosis or stent thrombosis accounting for 50–60% of cases which is similar to the 30–60% restenosis rates reported in cypher and second generation SF cases in previous reports . Analysis by micro‐CT in pathological specimens show evidences of the impact of SFs of inflammation and restenosis with both first and second generation DES .…”
Section: Discussionsupporting
confidence: 87%
See 1 more Smart Citation
“…Similarly, the most common modality of presentation for SF cases in either first generation or contemporary platforms in our analysis was in‐stent restenosis or stent thrombosis accounting for 50–60% of cases which is similar to the 30–60% restenosis rates reported in cypher and second generation SF cases in previous reports . Analysis by micro‐CT in pathological specimens show evidences of the impact of SFs of inflammation and restenosis with both first and second generation DES .…”
Section: Discussionsupporting
confidence: 87%
“…Our data suggests that there are many features common to SF cases that are shared by both contemporary and first generation platforms, such as the complexity of disease that predispose to SF including tortuous and calcified lesions as well as anatomical sites of occurrence, particularly in the right coronary artery and in overlapping stents. Indeed previous analyses have shown that tortuous and complex lesions are more commonly associated with SF and stent overlap whilst stent length and significant lesion angulation were independent predictors of SF .…”
Section: Discussionmentioning
confidence: 84%
“…In concert with previous reports, 37,38 DES fractures more often involved Cypher stents (Cordis™, Johnson & Johnson, NJ, USA), though the bare metal backbone Bx Velocity stent (Cordis™, Johnson & Johnson, NJ, USA) had fracture occurrence on par with other BMS designs (Supplementary Table 1). Differences in stent diameter were trivial between the two patient groups (Table 1); however, patients with stent fracture had longer stents.…”
Section: Resultssupporting
confidence: 82%
“…Although there have been a few reports showing no specific predilection for the location of stent fracture [1], the right coronary artery (RCA) appears to be favoured [1, 5, 18, 29, 30]. In a meta-analysis on stent fracture, the incidence rates of this complication in the RCA, left anterior descending artery (LAD), left circumflex artery (LCX), SVG, and left main artery were 56.4%, 30.4%, 10.9%, 1.7%, and smaller than 0.01%, respectively [5].…”
Section: Predictors and Mechanismsmentioning
confidence: 99%
“…Elsewhere, after a multivariate analysis, Park et al . found that stent length, use of the SES, minimum stent diameter, and maximal inflation pressure were the only significant predictors of stent fracture [30]. And finally, Kuramitsu et al .…”
Section: Predictors and Mechanismsmentioning
confidence: 99%