2020
DOI: 10.5194/amt-13-941-2020
|View full text |Cite
|
Sign up to set email alerts
|

Increase of the particle hit rate in a laser single-particle mass spectrometer by pulse delayed extraction technology

Abstract: Abstract. A single-particle mass spectrometer (SPMS) can provide a wealth of valuable information on chemical and physical parameters of individual particles in real time. One of the main performance criteria of the instrument is efficiency of particle detection (hit rate). Most SPMS instruments use constant electrical field (DC) extraction, where stationary high voltage is applied to the extraction electrodes. As the aerosol particles initially carry a certain charge, those with a high amount to charge can be… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
20
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
2

Relationship

4
6

Authors

Journals

citations
Cited by 20 publications
(20 citation statements)
references
References 33 publications
0
20
0
Order By: Relevance
“…The improvements and modifications from the SPAMS to the HP-SPAMS are comparatively presented below. The improvement in the SPAMS primarily includes the following three parts: the application of a concentration device, a delay extraction technology, and a multichannel acquisition technology (Chen et al, 2020;Li et al, 2018). First, the addition of the concentrator increases the injection flow rate by 6 times, which allows for an improved separation of the gas and particles.…”
Section: Instrumentation Of the Hp-spamsmentioning
confidence: 99%
“…The improvements and modifications from the SPAMS to the HP-SPAMS are comparatively presented below. The improvement in the SPAMS primarily includes the following three parts: the application of a concentration device, a delay extraction technology, and a multichannel acquisition technology (Chen et al, 2020;Li et al, 2018). First, the addition of the concentrator increases the injection flow rate by 6 times, which allows for an improved separation of the gas and particles.…”
Section: Instrumentation Of the Hp-spamsmentioning
confidence: 99%
“…Meanwhile, a delayed extraction technology is introduced to improve mass resolution and increase the hit rate by a factor of 2-4 for ambient particles (Y. Chen et al, 2020b). Also, the ion signals with high and low intensity are separated by multichannel acquisition technology and detected simultaneously, which makes the system's dynamic range more than 40 times the traditional data acquisition system and greatly improves the detection of ions with low signals (Shen et al, 2018;Zhong et al, 2021).…”
Section: Sampling Sites and Measurementsmentioning
confidence: 99%
“…The improvement in the SPAMS primarily includes three portions: the application of a concentration device, a delay extraction technology, and a multichannel acquisition technology (Chen et al, 2020;Li et al, 2018). First, the addition of the concentrator and negative (> 2000 at maximum half width) ion spectra are then significantly improved.…”
Section: Instrumentation Of the Hp-spamsmentioning
confidence: 99%