2021
DOI: 10.31897/pmi.2021.4.8
|View full text |Cite
|
Sign up to set email alerts
|

Indicator assessment of the reliability of mine ventilation and degassing systems functioning

Abstract: The gas emission control in the mines is operated by ventilation and degassing systems that ensure the aerological safety of the mines or minimize the aerological risks. The ventilation system of the mine and its individual sites includes a significant number of technical devices and equipment, and the air tubes are mainly mining workings, the condition of which determines the quality of the ventilation network (its capacity) and depends on a number of mining factors. Similarly, one of the most important eleme… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 1 publication
0
4
0
Order By: Relevance
“…The research into the flame radiation spectrum and methane, air and dust mixtures' explosion radiation spectrum was carried out by photoelectric method and aimed to obtain data on the nature of radiation energy wavelength distribution. This method enables spectrum recording with automatic dark signal subtraction and spectrograph wavelength calibration [22,23].…”
Section: Methodsmentioning
confidence: 99%
“…The research into the flame radiation spectrum and methane, air and dust mixtures' explosion radiation spectrum was carried out by photoelectric method and aimed to obtain data on the nature of radiation energy wavelength distribution. This method enables spectrum recording with automatic dark signal subtraction and spectrograph wavelength calibration [22,23].…”
Section: Methodsmentioning
confidence: 99%
“…The fulfillment of the requirements for a safe and reliable operation of the power supply system [20,21] directly depends on the state of the insulation of electrical installations. Timely detection of damage in 6-35 kV distribution networks and selective disconnection (selective protection) of damaged connections allow us not only to prevent the transition of SPGF to phase-to-phase short circuit, but also to significantly reduce the likelihood of electrical injuries to personnel.…”
Section: Problem Statementmentioning
confidence: 99%
“…where p1 is the probability of fan duct reliability, p2the probability of reliability of fans with electrical engines, If the 1   system sensibility to failure is added to the mathematical model for determining the probability of system reliability, it is needed to multiply the probability of subsystem reliability with the appropriate sensibility . i  For achieving the optimal probability of system reliability it is possible to conduct the optimisation of hot reserved components in the subsystems or elements in the cold reserve [8].…”
Section: Mathematical Model For Determining the Operation Reliability...mentioning
confidence: 99%