2007
DOI: 10.1002/rcm.3037
|View full text |Cite
|
Sign up to set email alerts
|

Indigo Carmine degradation by hypochlorite in aqueous medium monitored by electrospray ionization mass spectrometry

Abstract: The degradation of the dye Indigo Carmine by hypochlorite in aqueous solution was monitored by electrospray ionization mass spectrometry in the negative ion mode (ESI(—)‐MS). Hypochlorite was highly efficient in removing the color of aqueous solutions of the dye. ESI(—)‐MS monitoring showed that concomitant with the Indigo Carmine consumption two transient species appeared (detected as doubly charged anions) probably formed via a net insertion of two hydroxyl groups at the exocyclic CC bond followed by the in… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
14
0
4

Year Published

2007
2007
2022
2022

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 29 publications
(18 citation statements)
references
References 34 publications
(36 reference statements)
0
14
0
4
Order By: Relevance
“…[27][28][29] Electrospray ionization mass spectrometry (ESI-MS), because of its appealing and unique attributes, has rapidly becoming an alternative approach suitably employed to a direct monitoring of a increasing number of relevant environmental processes. [30][31][32][33][34][35][36][37][38][39][40] In these inquiries, the information provided by the MS (the m/z values of the ionic species) and MS/MS data (the fragmentation profiles of a given mass-selected ion) are meticulously evaluated aiming to propose chemical structures of products (and in some cases transient intermediates) likely formed in the condensed phase. 41 The identification of by-products arising from oxidative treatments, which can be more risky than the own precursors indeed, 42 is an important point that must be taken into consideration for the evaluation of the overall performance of a given process.…”
Section: Introductionmentioning
confidence: 99%
“…[27][28][29] Electrospray ionization mass spectrometry (ESI-MS), because of its appealing and unique attributes, has rapidly becoming an alternative approach suitably employed to a direct monitoring of a increasing number of relevant environmental processes. [30][31][32][33][34][35][36][37][38][39][40] In these inquiries, the information provided by the MS (the m/z values of the ionic species) and MS/MS data (the fragmentation profiles of a given mass-selected ion) are meticulously evaluated aiming to propose chemical structures of products (and in some cases transient intermediates) likely formed in the condensed phase. 41 The identification of by-products arising from oxidative treatments, which can be more risky than the own precursors indeed, 42 is an important point that must be taken into consideration for the evaluation of the overall performance of a given process.…”
Section: Introductionmentioning
confidence: 99%
“…Guaraldo et al, 2013, andDe Urzedo et al, 2007, studied the degradation of IC using a photoelectrocatalytic treatment with Ti/TiO 2 /WO 3 , and hypochlorite in aqueous medium, respectively. The formation of isatin-5-sulfonic acid as the main by-product resulting from the degradation was a common denominator in both investigations [36,37]. In order to confirm the identity of this by-product, an UVvis analysis was carried out with a standard of isatin-5-sulfonic acid (supplementary data 3).…”
Section: Degradation Of Indigo Carminementioning
confidence: 99%
“…Um grande número de artigos descrevem a aplicação dos POAs para degradar corantes em solução aquosa. Por exemplo, uma matriz composta por TiO 2 imobilizada nas superfícies internas de tubos de quartzo expostos continuamente a uma fonte de UV tem sido utilizada com sucesso para degradar vários corantes (Urzedo et al, 2007). Experiências em pequena escala mostraram que o sistema TiO 2 /luz solar possui alta eficiência na remoção da cor a partir de soluções aquosas de indigo carmim (Liao et al, 2009).…”
Section: Introductionunclassified