2004
DOI: 10.1093/rpd/nch220
|View full text |Cite
|
Sign up to set email alerts
|

Individual neutron monitoring in workplaces with mixed neutron/photon radiation

Abstract: EVIDOS (`evaluation of individual dosimetry in mixed neutron and photon radiation ®elds') is an European Commission (EC)-sponsored project that aims at a signi®cant improvement of radiation protection dosimetry in mixed neutron/photon ®elds via spectrometric and dosimetric investigations in representative workplaces of the nuclear industry. In particular, new spectrometry methods are developed that provide the energy and direction distribution of the neutron¯uence from which the reference dosimetric quantities… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2004
2004
2025
2025

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 25 publications
(6 citation statements)
references
References 19 publications
0
6
0
Order By: Relevance
“…For personal dosimeters the requirements are more restrictive. There are 2 different types of personal dosimeters that are attached to the body [1]: (i) passive recording dosimeters and (ii) active alarm dosimeters that respond in real time.…”
Section: Full Articlementioning
confidence: 99%
“…For personal dosimeters the requirements are more restrictive. There are 2 different types of personal dosimeters that are attached to the body [1]: (i) passive recording dosimeters and (ii) active alarm dosimeters that respond in real time.…”
Section: Full Articlementioning
confidence: 99%
“…Figure 2. Spectral neutron fluence per logarithmic binwidth as a function of energy at workplaces investigated at Krü mmel using BSs (dotted line) (1,2) and the directional spectrometer with silicon detectors (full line, MAXED unfolding with pre-information taken from BSs). E values show smaller changes with respect to direction.…”
Section: H P (10) and E For Different Directions Of A Person's Orientmentioning
confidence: 99%
“…Radiation Fields', see recent overviews (1)(2)(3) ], a series of new electronic neutron personal dosemeters and some passive ones have been irradiated at the nuclear power plant at Krü mmel in Germany. Places that are routinely visited for control measurements were chosen: a position in the control rod room underneath the reactor, another position near the top of the reactor and two places near a cask containing used fuel.…”
Section: Introduction Within the Ec Project Evidos ['Evaluation Of Inmentioning
confidence: 99%
“…The behaviour of the personal and area dosemeters in CANEL and SIGMA has been described previously (9) . At CANEL and SIGMA, the dosemeters Aloka PDM-313 and Siemens EPD N2 showed over-readings by more than a factor of two compared with the reference values, while others (Saphydose-n, DOS-2002, PADC track detectors from NRPB and devices based on superheated drop detectors like HpSLAB and BD-PND) showed deviations of <30%.…”
Section: C0: Cadarache Measurement Campaignmentioning
confidence: 99%