Influence of 4 Interfaces in the Assessment of Maximal Respiratory Pressures

Abstract: BACKGROUND: The measurement of maximal respiratory pressure (MRP) is a procedure widely used in clinical practice to evaluate respiratory muscle strength through the maximal inspiratory pressure (P Imax ) and maximal expiratory pressure (P Emax ). Its clinical applications include diagnostic procedures and evaluating responses to interventions. However, there is great variability in the equipment and measurement procedures. Understanding the impacts of the characteristics of different interfaces can augment th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
30
0
8

Year Published

2012
2012
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 25 publications
(38 citation statements)
references
References 33 publications
0
30
0
8
Order By: Relevance
“…20 The results found in this study indicate that older adults with PD and AD, even presenting anthropometric and cirtometric characteristics that are similar to those of healthy older adults, have greater compro- …”
Section: Discussionmentioning
confidence: 53%
“…20 The results found in this study indicate that older adults with PD and AD, even presenting anthropometric and cirtometric characteristics that are similar to those of healthy older adults, have greater compro- …”
Section: Discussionmentioning
confidence: 53%
“…Montemezzo et al 29 utilizou um sistema digital onde o software do computador tinha papel de identificar o período de um segundo onde houve maior sustentação de pressão e também o intervalo de um segundo de menor variabilidade. Desta forma realizava o registro tanto da pressão de pico quanto da sustentada, 15,29,30 facilitando o trabalho do examinador durante a medição das pressões respiratórias.…”
Section: Discussionunclassified
“…Desta forma realizava o registro tanto da pressão de pico quanto da sustentada, 15,29,30 facilitando o trabalho do examinador durante a medição das pressões respiratórias.…”
Section: Discussionunclassified
“…The equipment used in this investigation only directly supplies peak pressure values (the highest value during the maneuver) 22 . As such, sustained pressure values were determined by examining the pressure versus time curve provided by the manometer software.…”