Influence of cooling architecture on data center power consumption

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
37
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 56 publications
(37 citation statements)
references
References 26 publications
0
37
0
Order By: Relevance
“…Traditional cooling manages the temperature of the room as a whole, however, this is not as efficient as more targeted cooling. Moving from cooling the entire room to focused cooling of a row of servers, or even a specific rack, can achieve energy savings of up to 29% 60 , and is the subject of a Google patent granted in 2012 61 . This is becoming necessary because of the increase in rack density.…”
Section: Alternative Water Sourcesmentioning
confidence: 99%
“…Traditional cooling manages the temperature of the room as a whole, however, this is not as efficient as more targeted cooling. Moving from cooling the entire room to focused cooling of a row of servers, or even a specific rack, can achieve energy savings of up to 29% 60 , and is the subject of a Google patent granted in 2012 61 . This is becoming necessary because of the increase in rack density.…”
Section: Alternative Water Sourcesmentioning
confidence: 99%
“…ANSYS-IcePak software is commonly utilized to simulate the thermal characteristics of data center environment. 3,4 The second step in the CFD simulation involves solving the governing equations (Equations ( 1)-( 9)) for each cell, using finite volume method.…”
Section: The K-ε Turbulent Modelmentioning
confidence: 99%
“…A lot of researchers reported the drawbacks of traditional raised floor cooling architectures including (a) high pressure and temperature drops of cooling air in the raised floor plenum 3 and low supply air flow rate at racks intake, 4 (b) hot air recirculation and cold air bypass, 5 (c) hot spots for the servers placed at low levels of the racks, 6 and (d) un-efficient cooling system due to high losses. 7 Accordingly, a new data center cooling architecture named as in-row cooling architecture has been developed and rapidly sprit.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…A technique, proposed by Hosein Moazamigoodarzi et.al [33] in their paper can be a solution for improving the energy savings of the Data Centres with the implementation of computational fluid dynamics that can determine the temperature distributions and characteristic airflow for several cooling architectures like row-based, room-based and rack-based. The outcome of this proposed method may be treated as important methods to cool these architectures by inform the thermodynamics models of power consumptions.…”
Section: Literature Reviewmentioning
confidence: 99%