2020
DOI: 10.1016/j.ctro.2019.11.002
|View full text |Cite
|
Sign up to set email alerts
|

Influence of dose-averaged linear energy transfer on tumour control after carbon-ion radiation therapy for pancreatic cancer

Abstract: HighlightsHigh LET and high RBE of carbon ion made it a promising tool for treating pancreatic cancers.Dose averaged LET minimum within the GTV is significantly associated with local control.Outcome of CIRT in pancreatic cancers can be improved by modulating dose averaged LET within the GTV.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
47
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 42 publications
(48 citation statements)
references
References 21 publications
1
47
0
Order By: Relevance
“…A recent retrospective analysis on the C-ion treatment plans at NIRS suggest that the LET is positively associated to local control of pancreas tumors. In particular, patients with higher minimum dose-averaged LET values in the gross tumor volume had lower probability of local failure compared to those with minimum LET values below 40 keV/μm [ 127 ]. Approaches to extend the high-LET regions (LET painting [ 128 , 129 ]), also using multiple ions [ 130 ], in the tumor are very promising for next-generation particle therapy, especially when specific radioresistant regions have to be targeted such as hypoxic volumes [ 131 ] or cancer stem cell niches [ 132 ].…”
Section: Rbementioning
confidence: 99%
“…A recent retrospective analysis on the C-ion treatment plans at NIRS suggest that the LET is positively associated to local control of pancreas tumors. In particular, patients with higher minimum dose-averaged LET values in the gross tumor volume had lower probability of local failure compared to those with minimum LET values below 40 keV/μm [ 127 ]. Approaches to extend the high-LET regions (LET painting [ 128 , 129 ]), also using multiple ions [ 130 ], in the tumor are very promising for next-generation particle therapy, especially when specific radioresistant regions have to be targeted such as hypoxic volumes [ 131 ] or cancer stem cell niches [ 132 ].…”
Section: Rbementioning
confidence: 99%
“…It is worth mentioning here the work of Hagiwara et al [57], indicating the potential value of microdosimetric data for the clinical outcome of ion beam therapy. In this clinical-based investigation, the outcomes of local control and overall survival in pancreatic tumors are assessed with retrospective studies and examined in relation to the dose mean LET.…”
Section: Prospective Of Microdosimetry In the Clinicsmentioning
confidence: 90%
“…The clinical relationship between LET distribution within a tumor and tumor control has been explored in CIRT. Hagiwara and colleagues studied the influence of dose-averaged LET on CIRT-irradiated pancreatic tumor control in 2020 ( 48 ), retrospectively evaluating 18 patients treated with 55.2 Gy (RBE) CIRT at a median of 22 months. Four infield central local recurrences were noted.…”
Section: Let and Rbementioning
confidence: 99%
“…While dose was uniform throughout the tumor, LET was lower within the central compartment of the target volume, owing to how particle paths were overlapped to generate a spread out Bragg peak. Notably, local control was improved in those patients with higher minimum dose-averaged LET within the gross tumor volume (GTV), independent of the minimal dose and D98 delivered ( 48 ). Improved dose-averaged LET within the GTV may thereby improve local control, though the ability to fully control the LET within the tumor target may be limited by the LET distribution inherent to the carbon-ion beam, and the tumor’s relationship to nearby radiosensitive organs.…”
Section: Let and Rbementioning
confidence: 99%