1998
DOI: 10.1002/(sici)1521-4109(199809)10:12<852::aid-elan852>3.0.co;2-o
|View full text |Cite
|
Sign up to set email alerts
|

Influence of the HEPES Buffer on Electrochemical Reaction of the Copper(II)-Salicylaldoxime Complex

Abstract: The effect of the 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid (HEPES) on the redox process of copper(II)-salicylaldoxime complex [Cu(II)-SA] was studied. The measurements were performed on a hanging mercury drop electrode (HMDE) using various electrochemical techniques. The presence of the HEPES buffer (pH 8.0) doubled the reduction current of the Cu(II)-SA complex, whereas the reduction potential shifted to more positive values (about 50 mV). The results obtained indicate that the presence of the HEPES… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(2 citation statements)
references
References 28 publications
0
2
0
Order By: Relevance
“…We hypothesize the Pu and Bk reduction likely resulted from radiolysis provided by the high-energy X-ray beam. In addition, sulfonic acid buffers -the matrices in which these measurements were collected -are known to enhance or facilitate redox activity (Cuculic ´et al, 1998), yet it should be noted that reductive decomposition of Pu and Bk was also observed in other buffers (i.e. TRIS buffer).…”
Section: Discussionmentioning
confidence: 99%
“…We hypothesize the Pu and Bk reduction likely resulted from radiolysis provided by the high-energy X-ray beam. In addition, sulfonic acid buffers -the matrices in which these measurements were collected -are known to enhance or facilitate redox activity (Cuculic ´et al, 1998), yet it should be noted that reductive decomposition of Pu and Bk was also observed in other buffers (i.e. TRIS buffer).…”
Section: Discussionmentioning
confidence: 99%
“…In this study, we carefully examined the electrochemical properties of Au, Pt, and GC electrodes in three biological buffers, namely Tris, phosphate, and HEPES. , This study specifically focused on how ions, pH values, and the redox phenomenon on electrode surfaces affect the electrochemical windows of the three electrodes. By mixing the solution with HCl, H 2 SO 4 , and NaOH solutions, we were able to adjust their pH values from 6.0 to 9.0, allowing us to illustrate the effects of pH levels and type of ions involved.…”
Section: Introductionmentioning
confidence: 99%