2020
DOI: 10.1016/j.conbuildmat.2020.120425
|View full text |Cite
|
Sign up to set email alerts
|

Inhibition effect and mechanism of polyacrylamide for steel corrosion in simulated concrete pore solution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
14
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 39 publications
(14 citation statements)
references
References 77 publications
0
14
0
Order By: Relevance
“…The C 1s spectra of the control and SRB systems were fitted by the curve of three peaks. The peaks at 284.8, 286.1, 288.1, and 289.1 eV are for C–S/C–H/C–C, C–N, CO, , which could be attributed to the adsorption of HPAM and SPS. The fitted N 1p high-resolution spectra are shown in Figure d.…”
Section: Resultsmentioning
confidence: 97%
See 2 more Smart Citations
“…The C 1s spectra of the control and SRB systems were fitted by the curve of three peaks. The peaks at 284.8, 286.1, 288.1, and 289.1 eV are for C–S/C–H/C–C, C–N, CO, , which could be attributed to the adsorption of HPAM and SPS. The fitted N 1p high-resolution spectra are shown in Figure d.…”
Section: Resultsmentioning
confidence: 97%
“…33 The organic O peak at 531.8 eV was attributed to EPS secreted by SRB. 34 The fitted C 1s high- 30,36 which could be attributed to the adsorption of HPAM and SPS. The fitted N 1p high-resolution spectra are shown in Figure 5d.…”
Section: Analyses Of Surface Morphology and Contact Anglementioning
confidence: 93%
See 1 more Smart Citation
“…To quantitatively analyze the anti-corrosion performance of MCIs on the reinforced concrete that underwent varying degrees of chloride erosion, the equivalent circuit model shown in Figure 4 was used to fit the Nyquist plots [ 24 , 25 ], and the fitted results are listed in Table 3 . In the equivalent circuit model in Figure 4 , R s denotes the resistance of the sodium chloride solution during chloride erosion, R f denotes the resistance of the protective MCIs-molecule film on the steel bar surface, and R ct denotes the charge transfer resistance.…”
Section: Resultsmentioning
confidence: 99%
“…In the civil engineering field, polyacrylamides are commonly utilized as the viscosity modifying admixtures [3][4][5]. It can improve the yield stress of the cementing material while reducing the deformation of the material due to its own weight, which is the key of additive manufacturing concrete.…”
Section: Introductionmentioning
confidence: 99%