2011
DOI: 10.14797/mdcj-7-1-40
|View full text |Cite
|
Sign up to set email alerts
|

Initial Clinical Experience Of Total Cardiac Replacement With Dual Heartmate-II®Axial Flow Pumps For Severe Biventricular Heart Failure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
24
0
4

Year Published

2011
2011
2018
2018

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 34 publications
(28 citation statements)
references
References 7 publications
0
24
0
4
Order By: Relevance
“…6 In contrast, intrapericardial placement of a HeartWare HVAD for RV support avoids interference with the outflow path of the left-sided pump. Thus, despite the logistical complexities in their management, nonidentical CF device pairings can provide successful long-term biventricular support.…”
Section: Discussionmentioning
confidence: 99%
“…6 In contrast, intrapericardial placement of a HeartWare HVAD for RV support avoids interference with the outflow path of the left-sided pump. Thus, despite the logistical complexities in their management, nonidentical CF device pairings can provide successful long-term biventricular support.…”
Section: Discussionmentioning
confidence: 99%
“…[23][24][25][26][27] Although such devices have been designed and optimized (anatomically and physiologically) for LV assist, investigators have been able to adapt them for use on the right side. The adaptations include spacers to adjust inflow cannula depth of penetration into the RV and constrictors on the outflow graft to decrease output to the low-pressure, low-resistance pulmonary circuit.…”
Section: Discussionmentioning
confidence: 99%
“…22 Recently, encouraging results have been obtained with miniaturized LVADs used for RV support. [23][24][25][26][27] However, these devices are not ideally suited for implantation in the right heart, and therefore, research on VADs remains necessary. [28][29][30][31][32][33][34][35][36][37][38][39][40] The Synergy Micro-Pump (CircuLite Inc, Saddle Brook, NJ) is the size of an AA battery, connects to the heart via an 8-mm-diameter by 20-cm-long inflow cannula, has a pumping capacity of up to ϳ4.25 liters/min, and is small enough to be placed in a subcutaneous pocket.…”
mentioning
confidence: 99%
“…Newer-generation long-term LVADs (including the Jarvik 2000 [86 ] and the HeartWare [88 ]) have been used as RVADs (for biventricular support). Dual HeartMate II continuous-flow VADs have been used for total cardiac replacement (complete heart resection) [89]. The superiority of a continuous-flow long-term LVAD over its predecessor pulsatile LVAD (HeartMate II vs. HeartMate I) for destination therapy was shown in a randomized study: improved probability of survival free from stroke and device failure at 2 years (composite end-point), better actuarial survival, better estimated 1 and 2-year survival, significant reductions in major adverse events [91].…”
Section: Risk Factors For Mortality In Short-term Mechanical Circulatmentioning
confidence: 99%
“…FDA approval for DT. Applied as continuous-flow total cardiac replacement (dual pumps -heart resection)[89]. Jarvik 2000 (Jarvik Heart Inc., New York, NY)Newer-generation, long-term, intracardiac, continuous axial flow LVAD.…”
mentioning
confidence: 99%