Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Adalimumab (ADL, Humira ® , reference product), an anti-TNF-α biologic, has transformed the treatment of chronic, immune-mediated inflammatory diseases. However, the high cost of ADL therapy has driven the development of more affordable ADL biosimilars, agents with no clinically meaningful differences from the reference product. This review summarizes the product attributes of reference ADL and the nine ADL biosimilars approved and available in the USA in relation to patient experience of injection-site pain (ISP). Product formulation, delivery volume and device features (e.g., type and needle gauge size) influence patient experience of ISP with potential clinical consequences. Citrate-free formulations generally cause less ISP; injection volumes of > 1.5 ml may be associated with increased ISP. Reference ADL and all ADL biosimilars offer a citrate-free formulation, and reference ADL and four ADL biosimilars offer a high-concentration solution that allows a smaller injection volume. All available ADL products are injected subcutaneously using either a pre-filled pen (PFP) or pre-filled syringe (PFS). Patients prefer the PFP, but the PFS permits better control over the speed and duration of injection. Smaller (29-gauge) needle outer diameter is associated with less ISP; reference ADL and seven ADL biosimilars offer a device with a 29-gauge needle. In the USA, an approved biosimilar can be designated “interchangeable,” allowing pharmacy-level substitution, where state law permits. In the USA, two ADL biosimilars have received interchangeability designation; others are seeking interchangeability designation from the Food and Drug Administration ( n = 2), are being evaluated in clinical studies to support interchangeability ( n = 2), or do not have/are not seeking interchangeability designation ( n = 3). Product-related attributes influence patient experience of ISP caused by subcutaneous ADL injection. Reference ADL and ADL biosimilar products differ in their attributes, so discussion with patients about treatment options is essential to optimize adherence and outcomes. Supplementary Information The online version contains supplementary material available at 10.1007/s12325-024-02818-9.
Adalimumab (ADL, Humira ® , reference product), an anti-TNF-α biologic, has transformed the treatment of chronic, immune-mediated inflammatory diseases. However, the high cost of ADL therapy has driven the development of more affordable ADL biosimilars, agents with no clinically meaningful differences from the reference product. This review summarizes the product attributes of reference ADL and the nine ADL biosimilars approved and available in the USA in relation to patient experience of injection-site pain (ISP). Product formulation, delivery volume and device features (e.g., type and needle gauge size) influence patient experience of ISP with potential clinical consequences. Citrate-free formulations generally cause less ISP; injection volumes of > 1.5 ml may be associated with increased ISP. Reference ADL and all ADL biosimilars offer a citrate-free formulation, and reference ADL and four ADL biosimilars offer a high-concentration solution that allows a smaller injection volume. All available ADL products are injected subcutaneously using either a pre-filled pen (PFP) or pre-filled syringe (PFS). Patients prefer the PFP, but the PFS permits better control over the speed and duration of injection. Smaller (29-gauge) needle outer diameter is associated with less ISP; reference ADL and seven ADL biosimilars offer a device with a 29-gauge needle. In the USA, an approved biosimilar can be designated “interchangeable,” allowing pharmacy-level substitution, where state law permits. In the USA, two ADL biosimilars have received interchangeability designation; others are seeking interchangeability designation from the Food and Drug Administration ( n = 2), are being evaluated in clinical studies to support interchangeability ( n = 2), or do not have/are not seeking interchangeability designation ( n = 3). Product-related attributes influence patient experience of ISP caused by subcutaneous ADL injection. Reference ADL and ADL biosimilar products differ in their attributes, so discussion with patients about treatment options is essential to optimize adherence and outcomes. Supplementary Information The online version contains supplementary material available at 10.1007/s12325-024-02818-9.
IntroductionMultiple sclerosis (MS) typically requires life-long management with disease-modifying therapies (DMTs). Many DMTs require regular self-injection, and can be associated with injection site reactions, pain, and needle/injection phobia—but these can be addressed by improvements in autoinjector design. The aim of this study was to investigate patient satisfaction and preference for BETACONNECT™ (Bayer Pharma AG), a novel interferon beta-1b autoinjector.MethodsPatients in Germany performing self-injections using BETACONNECT took part in the study. Data were collected through an online 15-min structured survey. Participants rated their experience with BETACONNECT on a 6-point scale and those satisfied with BETACONNECT were asked to describe the reason using a free-text box.ResultsOne-hundred and eighteen patients with MS completed the survey. Ninety percent preferred BETACONNECT to their previous injection method (only 4% previously used manual injections, so most had previously used other autoinjectors). Ninety-two percent were very confident/confident in their ability to perform an injection using BETACONNECT. The most common free-text responses to “Why are you satisfied with the BETACONNECT™ autoinjector?” were ease of use (46%), less irritation/pain at the injection site (33%), and smoother injections (24%). Features considered most useful were automated injections (98%), adjustable injection speed (98%), and adjustable injection depth (98%). Ninety-seven percent thought it was easy to know when an injection was complete and 95% agreed/strongly agreed it was easy to learn to use the autoinjector. Seventy-three percent agreed that the quietness and effortlessness of the BETACONNECT reduced their level of injection anxiety, 92% that its size and shape makes it easy to handle during injections, and 67% that it decreases injection site pain. Eighty percent of those using the reminder function thought they were less likely to miss an injection.ConclusionPatients with MS self-injecting interferon beta-1b expressed a high level of satisfaction and preference for BETACONNECT. Thus, BETACONNECT represents a valid option to improve patients’ overall injection experience.FundingBayer HealthCare Pharmaceuticals.Electronic supplementary materialThe online version of this article (doi:10.1007/s40120-015-0036-y) contains supplementary material, which is available to authorized users.
IntroductionPatients with multiple sclerosis (MS) generally undergo long-term treatment with disease-modifying therapies (DMTs). In the US, patients taking glatiramer acetate, interferon beta-1a, or interferon beta-1b, typically use a mechanical autoinjector. Recent survey results have shown that using an electronic autoinjector, such as BETACONNECT™ (Bayer Pharma AG) for interferon beta-1b/Betaseron® (Bayer Pharma AG) may reduce injection discomfort and increase patient satisfaction with treatment. The aim of the current survey was to assess patient perceptions of BETACONNECT compared with mechanical autoinjectors using a survey integrated with demonstrations and simulated injections with BETACONNECT.MethodsPatients with MS currently using mechanical autoinjectors for glatiramer acetate/Copaxone® (Teva Pharmaceuticals USA, Inc.), interferon beta-1a/Rebif® (EMD Serono Inc.), or interferon beta-1b/Extavia® (Novartis Pharmaceuticals Corp.), participated in a 60-min in-person interview. Patients rated the importance of 18 ideal autoinjector attributes, and the performance of their current autoinjectors across these attributes. BETACONNECT was demonstrated and patients performed simulated injections with BETACONNECT before rating it across the same attributes. Patient overall autoinjector preference was assessed.ResultsNinety patients completed the survey: 63 were using autoinjectors for Copaxone, 25 for Rebif, and 2 for Extavia. BETACONNECT scored higher than mechanical autoinjectors across all 18 attributes. The top attributes of an ideal autoinjector were the injection process is easy overall, easy to push the button to start the injection, and autoinjector is comfortable to hold during injections. Unique BETACONNECT features most valued by patients were the built-in dwell time, self-check function, greater ability to customize injections, adjustment of injection speed, low injection noise, and automatic needle retraction. Overall, 75 out of 90 patients (83%) expressed a preference for BETACONNECT over their current autoinjector.ConclusionBETACONNECT attributes and features were highly rated by patients, compared with both an ideal autoinjector and their current mechanical autoinjectors. These findings suggest that the use of BETACONNECT may increase patient satisfaction and potentially increase overall medication adherence.FundingBayer HealthCare Pharmaceuticals.Electronic supplementary materialThe online version of this article (doi:10.1007/s40120-016-0047-3) contains supplementary material, which is available to authorized users.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.