2023
DOI: 10.3390/ijms24108776
|View full text |Cite
|
Sign up to set email alerts
|

Innovative Rocuronium Bromide Topical Formulation for Targeted Skin Drug Delivery: Design, Comprehensive Characterization, In Vitro 2D/3D Human Cell Culture and Permeation

Abstract: Cutaneous squamous cell carcinoma (cSCC) is the second-most common type of non-melanoma skin cancer and is linked to long-term exposure to ultraviolet (UV) radiation from the sun. Rocuronium bromide (RocBr) is an FDA-approved drug that targets p53-related protein kinase (PRPK) that inhibits the development of UV-induced cSCC. This study aimed to investigate the physicochemical properties and in vitro behavior of RocBr. Techniques such as thermal analysis, electron microscopy, spectroscopy and in vitro assays w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 35 publications
0
4
0
Order By: Relevance
“…The thermal transitions of raw HI-TOPK-032 were determined using a Discovery Differential Scanning Calorimeter 250 with ultra-high purity (UHP) nitrogen gas (Airgas, Air Liquide, Palm Beach, FL, USA) with a flow rate of 50 mL/min and TRIOS v5.6.0.87 software for analysis (DSC250 with T-Zero ® Technology (TA Instruments, New Castle, DE, USA). As described in previously published methods [27,28], briefly, 2-5 mg of the sample was packed into hermetic anodized aluminum T-Zero ® DSC pan, and aluminum lids were hermetically sealed using a T-Zero ® hermetic press (TA Instruments, New Castle, DE, USA). The reference pan was an empty, hermetically sealed T-Zero ® aluminum pan.…”
Section: Differential Scanning Calorimetry (Dsc)mentioning
confidence: 99%
See 3 more Smart Citations
“…The thermal transitions of raw HI-TOPK-032 were determined using a Discovery Differential Scanning Calorimeter 250 with ultra-high purity (UHP) nitrogen gas (Airgas, Air Liquide, Palm Beach, FL, USA) with a flow rate of 50 mL/min and TRIOS v5.6.0.87 software for analysis (DSC250 with T-Zero ® Technology (TA Instruments, New Castle, DE, USA). As described in previously published methods [27,28], briefly, 2-5 mg of the sample was packed into hermetic anodized aluminum T-Zero ® DSC pan, and aluminum lids were hermetically sealed using a T-Zero ® hermetic press (TA Instruments, New Castle, DE, USA). The reference pan was an empty, hermetically sealed T-Zero ® aluminum pan.…”
Section: Differential Scanning Calorimetry (Dsc)mentioning
confidence: 99%
“…The crystallinity of raw HI-TOPK-032 powder was determined by X-ray powder diffraction (XRPD) analysis using similar conditions to those reported previously [17,26,28]. XRPD patterns of raw HI-TOPK-032 powder were recorded using a PANalytical X'pert diffractometer (PANalytical Inc., Westborough, MA, USA) equipped with a programmable incident beam slit and an X'celerator detector at room temperature.…”
Section: X-ray Powder Diffraction (Xrpd)mentioning
confidence: 99%
See 2 more Smart Citations