“…The lithium atoms occupy six independent positions and are surrounded by four or five oxygen atoms. The symmetry of both Y 3+ and Gd 3+ ion sites is C1 (distorted cube) [8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25]. Both LGBO and LYBO crystallizes in the monoclinic system with the space group P2 1 /c with the refined parameters measured on the fibers single crystals grown by micro-pulling down technique as can seen in Table 1.…”
Section: +mentioning
confidence: 99%
See 1 more Smart Citation
“…The lithium atoms occupy six independent positions and are surrounded by four or five oxygen atoms. The symmetry of both Y 3+ and Gd 3+ ion sites is C1 (distorted cube) [8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25]. Both LGBO and LYBO crystallizes in the monoclinic system with the space group P2 1 /c with the refined parameters measured on the fibers single crystals grown by micro-pulling down technique as can seen in Table 1.…”
Section: +mentioning
confidence: 99%
“…Van Eijk et al [9,10] has suggested that LGBO crystals will have a high light yield (about 15,000 photons/MeV) and short decay times (s % 27 ns). As 6 Li, 10 B, Gd,155 Gd isotopes can react with the neutrons and then produce charged particles c rays with…”
Section: +mentioning
confidence: 99%
“…When testing LYSO, it was found that the observed lifetime (∼46 ns) was longer than 40 ns reported in the literature. 25 This led us to investigate LYSO response times and energy resolutions for various scintillator geometries. Annihilation energy spectra were generated using two similar Hamamatsu R1924A single channel PMTs each coupled to one of the two different sizes of LYSO: a block measuring 30 × 15 × 15 mm 3 and a thin rectangle measuring 30 × 22 × 2 mm 3 coupled to the PMT at the 2 × 22 mm 2 face.…”
Section: A Testing Of Scintillators and Mounting Arrangementsmentioning
confidence: 99%
“…A 1 mm diameter 18 F point source was positioned in the center of scanner FOV emitting mono-energetic back-to-back 511 keV photons. In the simulation, the energy window was set to 250-700 keV, and the energy resolution was based on the reported energy resolutions for each of the scintillator materials.…”
Section: Validation Of Monte Carlo Simulation Tool With the Vista Sca...mentioning
confidence: 99%
“…The spatial resolution across the FOV of the VISTA scanner was simulated by moving a 0.5 mm diameter 18 F point source, with 5 mm increments along radial direction, from central point to 25 mm away from the central slice. For each of the source positions, source image was reconstructed using two dimensional filtered backprojection (FBP) method.…”
Section: Validation Of Monte Carlo Simulation Tool With the Vista Sca...mentioning
confidence: 99%