2019
DOI: 10.1016/j.jbiomech.2018.11.032
|View full text |Cite
|
Sign up to set email alerts
|

Instrumentation of off-the-shelf ultrasound system for measurement of probe forces during freehand imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 20 publications
(10 citation statements)
references
References 21 publications
0
10
0
Order By: Relevance
“…Ultrasound is a cost-effective and non-invasive imaging modality best used to investigate soft tissue properties. If used in conjunction with force feedback the user can account for the applied load deforming tissue during imaging 7 . Computer tomography (CT) and magnetic resonance (MR) imaging are also used to investigate soft tissue properties and, although more cost prohibitive, allow accurate measurement of tissue thickness.…”
Section: Background and Summarymentioning
confidence: 99%
See 2 more Smart Citations
“…Ultrasound is a cost-effective and non-invasive imaging modality best used to investigate soft tissue properties. If used in conjunction with force feedback the user can account for the applied load deforming tissue during imaging 7 . Computer tomography (CT) and magnetic resonance (MR) imaging are also used to investigate soft tissue properties and, although more cost prohibitive, allow accurate measurement of tissue thickness.…”
Section: Background and Summarymentioning
confidence: 99%
“…Ultrasound imaging was performed using an ACUSON S3000 TM (Siemens Healthcare, Erlangen, Germany), instrumented 7 with a six degree-of-freedom (6-DoF) Nano25 load cell (ATI Industrial Automation, Apex, North Carolina), a VN-100 inertial measurement unit (IMU) (VectorNav, Dallas, Texas), and an optical tracking smart cluster (Northern Digital Inc., Waterloo, ON) ( Fig. 2).…”
Section: Ultrasound Image Acquisitionmentioning
confidence: 99%
See 1 more Smart Citation
“…Additionally, an indenter probe was created to measure bulk tissue response during loading. The three surgical tools were demonstrated in a previous study 19 , as was the custom LabVIEW (National Instruments, Dallas, TX) program 19,22 for instrumentation of an ultrasound to measure load and track position. The indenter is a 10 mm diameter stainless-steel sphere attached to a stainless-steel cylinder and is interchangeable with the scalpel blade holder and retractor (Fig.…”
Section: Background and Summarymentioning
confidence: 99%
“…In general, there are three main ways to implement 3D ultrasound reconstruction: 1) A freehand system equipped with multiple positioning sensors [8,9,11,[16][17][18][19][20][21]26]. This design is relatively lightweight.…”
Section: Introductionmentioning