2017
DOI: 10.1016/j.psep.2017.09.009
|View full text |Cite
|
Sign up to set email alerts
|

Integration of reverse osmosis desalination with hybrid renewable energy sources and battery storage using electricity supply and demand-driven power pinch analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
21
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 36 publications
(21 citation statements)
references
References 28 publications
0
21
0
Order By: Relevance
“…Using design values of DOW company tables and the number of elements it is possible to calculate the number of steps to achieve a desired recovery. After determining the number of stages, using a specified stage ratio (Equation 3) the number of pressure vessels within each stage can be achieved from Equations (4) and (5). 64 In this equation Q p is rate of permeate flow (m 3 /h) and S m is membrane area (m 2 ).…”
Section: Ro System Designmentioning
confidence: 99%
See 2 more Smart Citations
“…Using design values of DOW company tables and the number of elements it is possible to calculate the number of steps to achieve a desired recovery. After determining the number of stages, using a specified stage ratio (Equation 3) the number of pressure vessels within each stage can be achieved from Equations (4) and (5). 64 In this equation Q p is rate of permeate flow (m 3 /h) and S m is membrane area (m 2 ).…”
Section: Ro System Designmentioning
confidence: 99%
“…Several methods can be applied to produce fresh water from saline water . One of the most efficient methods that can provide fresh water at a favorable cost is reverse osmosis system . Producing the fresh water by applying reverse osmosis technology attracts the researcher's attention around the world.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…A rectifier can convert AC electricity generated by wind turbines (WTs) to DC for storage in a battery bank (BB). Three electrical losses were considered: during energy conversion in the PV panels and WTs; during charging and discharging of the battery; and during net AC-to-DC conversion [29]. Figure 3 is a schematic representation of a MBR system.…”
Section: System Configuration and Energy Management Strategymentioning
confidence: 99%
“…2. An appropriate battery capacity (BC) and the outsourced needed electricity (NE) for one operational year were determined for each sub-scenario using the storage cascade table (SCT) of PoPA [29]. 3.…”
mentioning
confidence: 99%