2018
DOI: 10.1007/s10916-018-1101-8
|View full text |Cite
|
Sign up to set email alerts
|

Inter and Intra-Rater Reliability of Short-Term Measurement of Heart Rate Variability on Rest in Diabetic Type 2 Patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
33
0
1

Year Published

2020
2020
2022
2022

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 38 publications
(39 citation statements)
references
References 30 publications
3
33
0
1
Order By: Relevance
“…Farah et al 15 found that the inter-researcher reproducibility was lower than the intra-researcher reproducibility in 27 healthy adolescents and concluded that the same researcher should perform the HRV data signal processing of short-term recordings 15 . In the same way, Bassi et al reported similar results to the obtained by Farah et al 15 in a cohort of 44 middle-aged adults with type 2 diabetes 16 . However, little is known about how much the observers' decisions influence HRV parameters measured with heart rate monitors (e.g., Polar) in different age-range populations including a relatively larger sample size than in the previous studies 15,16 .…”
Section: Sdnnsupporting
confidence: 76%
See 1 more Smart Citation
“…Farah et al 15 found that the inter-researcher reproducibility was lower than the intra-researcher reproducibility in 27 healthy adolescents and concluded that the same researcher should perform the HRV data signal processing of short-term recordings 15 . In the same way, Bassi et al reported similar results to the obtained by Farah et al 15 in a cohort of 44 middle-aged adults with type 2 diabetes 16 . However, little is known about how much the observers' decisions influence HRV parameters measured with heart rate monitors (e.g., Polar) in different age-range populations including a relatively larger sample size than in the previous studies 15,16 .…”
Section: Sdnnsupporting
confidence: 76%
“…To our knowledge, only two previous studies have tested either the inter-or intra-researcher reproducibility of the selected R-R interval period using the Kubios software 15,16 . Farah et al 15 found that the inter-researcher reproducibility was lower than the intra-researcher reproducibility in 27 healthy adolescents and concluded that the same researcher should perform the HRV data signal processing of short-term recordings 15 .…”
Section: Sdnnmentioning
confidence: 99%
“…Cronbach’s α was used to evaluate internal consistency, considering values between 0.70 and 0.95 to indicate good internal consistency [ 12 ]. Test–retest reliability for the seven days interval was assessed with intraclass correlation coefficient (ICC), standard error of measurement (SEM), and the minimal detectable change (MDC) [ 21 ]. We used the following formula to calculate the SEM: standard deviation x √(1−ICC).…”
Section: Methodsmentioning
confidence: 99%
“…For the interpretation of the ICC value, the Fleiss study classification was used: for values below 0.40, the reliability was considered low; between 0.40 and 0.75, moderate; between 0.75 and 0.90, substantial; and greater than 0.90, excellent [ 22 ]. For the construct validity, we hypothesized a magnitude of correlation greater than 0.50 (similar construct) with the original NDI, between 0.30–0.50 with the functional capacity domain of the SF-36 (related but different constructs), and less than 0.30 with the others research instruments (unrelated constructs) [ 21 ].…”
Section: Methodsmentioning
confidence: 99%
“…Além do ECG, o registro dos impulsos elétricos cardíacos pode ser feito por meio de dispositivos portáteis, tais como os cardiofrequencímetros, que são uma alternativa prática, com menor custo que o ECG e possibilitam a mensuração dos intervalos RR tanto na área científica como na prática clínica (Bassi et al, 2018;Caminal et al, 2018), porém para evitar erros nas interpretações clínicas dos parâmetros derivados da VFC, a validade e a reprodutibilidade dos dispositivos portáteis devem ser avaliadas (Plaza-Florido et al, 2021). Sendo assim, o presente estudo teve como objetivo revisar evidências científicas sobre a validade de cardiofrequencímetros para a mensuração da VFC na condição de repouso em diferentes populações.…”
Section: Introductionunclassified