Inter-observer and Intra-observer Variability in Volume Measurements of the Lower Extremity Using Perometer

Abstract: Background: The swelling of the extremities seen in lymphedema can be measured with many different volumetric devices; however, many methods lack important characteristics including reproducibility and independence from the subjectivity and skill of the operator. The aim of this study was to validate the use of the Perometer Ò as a possible standard for volumetric measurement methods based on the inter-observer and intraobserver variability when using a standard method of Perometry Ò. Methods and Results: Volu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(3 citation statements)
references
References 14 publications
0
3
0
Order By: Relevance
“…Current techniques to determine volumes locally are water displacement, girth, and caliper measurements, MRI imaging, X-ray tomography, ultrasound, and three dimensional imaging. 21,[31][32][33][34] The distance between girth measurements on a limb determines the length of the segment that is used in the calculation of geometric volume. This segment length has not been standardized, 18 and varies from 1 cm, 6 3 cm, 27,35-37 4 cm, 6,20,25,28,[38][39][40][41][42][43] 5 cm 44 to 10 cm and more and in between.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Current techniques to determine volumes locally are water displacement, girth, and caliper measurements, MRI imaging, X-ray tomography, ultrasound, and three dimensional imaging. 21,[31][32][33][34] The distance between girth measurements on a limb determines the length of the segment that is used in the calculation of geometric volume. This segment length has not been standardized, 18 and varies from 1 cm, 6 3 cm, 27,35-37 4 cm, 6,20,25,28,[38][39][40][41][42][43] 5 cm 44 to 10 cm and more and in between.…”
Section: Discussionmentioning
confidence: 99%
“…14,18,[44][45][46][47][48][49] The Perometer measures a change in volume every 2.54-4.7 mm. 8,21,28,42,50,51 In contrast, the slice thickness using the PAM is 1.1 mm or less measuring an arm. This enables extreme local volume determination.…”
Section: Discussionmentioning
confidence: 99%
“…To cover the average size of the human tibial metaphysis, the ROI ankle was chosen at a location 5 cm proximal from the medial malleolus [ 30 ]. There exists a dearth of information concerning the volume variability between contralateral limbs in healthy subjects such as may be caused by leg dominance [ 31 ]. This study demonstrates no significant differences in the overall volume and the respective ROI between right and left leg in our study participants (Fig.…”
Section: Discussionmentioning