2016
DOI: 10.5194/amt-9-4471-2016
|View full text |Cite
|
Sign up to set email alerts
|

Intercomparison of stratospheric nitrogen dioxide columns retrieved from ground-based DOAS and FTIR and satellite DOAS instruments over the subtropical Izana station

Abstract: Abstract.A 13-year analysis (2000)(2001)(2002)(2003)(2004)(2005)(2006)(2007)(2008)(2009)(2010)(2011)(2012) of the NO 2 vertical column densities derived from ground-based (GB) instruments and satellites has been carried out over the Izaña NDACC (Network for the Detection of the Atmospheric Composition Change) subtropical site. Ground-based DOAS (differential optical absorption spectroscopy) and FTIR (Fourier transform infrared spectroscopy) instruments are intercompared to test mutual consistency and then used… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
3
3
2
1

Relationship

4
5

Authors

Journals

citations
Cited by 13 publications
(18 citation statements)
references
References 52 publications
(70 reference statements)
0
18
0
Order By: Relevance
“…Measurements are made during twilight, at sunrise, and at sunset, but only sunset measurements are used here for signal-to-noise reasons (larger NO 2 column) and as these happen closer in time to the early-afternoon overpass of S5P. NDACC intercomparison campaigns (Roscoe et al, 1999;Vandaele et al, 2005) conclude an uncertainty of about 4 %-7 % on the slant column density. After conversion of the slant column into a vertical column using a zenith-sky AMF, and for the latest version of the data processing, the uncertainty on the vertical column is estimated to be on the order of 10 %-14 % (Yela et al, 2017;Bognar et al, 2019).…”
Section: Ndacc Zenith-sky Doas Datamentioning
confidence: 99%
“…Measurements are made during twilight, at sunrise, and at sunset, but only sunset measurements are used here for signal-to-noise reasons (larger NO 2 column) and as these happen closer in time to the early-afternoon overpass of S5P. NDACC intercomparison campaigns (Roscoe et al, 1999;Vandaele et al, 2005) conclude an uncertainty of about 4 %-7 % on the slant column density. After conversion of the slant column into a vertical column using a zenith-sky AMF, and for the latest version of the data processing, the uncertainty on the vertical column is estimated to be on the order of 10 %-14 % (Yela et al, 2017;Bognar et al, 2019).…”
Section: Ndacc Zenith-sky Doas Datamentioning
confidence: 99%
“…Since the pioneering ages of NO 2 column measurements from space with ERS-2 GOME in the mid-1990s, ground-based UV-visible DOAS measurements at twilight have served as a reference for the validation of NO 2 total column data over unpolluted stations and of NO 2 stratospheric column data from all nadir UV-visible satellites to date (e.g., Lambert et al, 1997a, b;Petritoli et al, 2003;Celarier et al, 2008;Ionov et al, 2008;Gruzdev and Elokhov, 2010;Dirksen et al, 2011;Hendrick et al, 2011;Robles-Gonzalez et al, 2016). Here as well, S5p TROPOMI stratospheric NO 2 column data are compared to the correlative measurements acquired by ZSL-DOAS (Zenith-Scattered Light Differential Optical Absorption Spectroscopy)…”
Section: Ndacc Zenith-sky Doas Datamentioning
confidence: 99%
“…10, lower panel). There are multiple causes affecting the magnitude of the measured column, namely, the hour of the measurements, field of view, and vertical sensitivity (Piters et al, 2011;Robles-Gonzalez et al, 2016); however, these factors should not affect the observed trends. Table 5 displays the results of the trends from the regression model using the monthly data.…”
Section: Generalmentioning
confidence: 99%
“…The transition between RASAS and RASAS-II required a RASAS correction due to a degradation of the detector response since mid-2006, at a rate of 4.33 % year −1 . The details of the RASAS-II instrument have been previously published in Puentedura et al (2012) and Robles-Gonzalez et al (2016). The spectrometers were installed in the top terrace of the Izaña Atmospheric Observatoy, run by the CIAI (Centro de Investigación Atmosférica de Izaña), belonging to the Agencia Estatal de Meteorología (AEMET, Spain), on the slopes of the Teide volcano, Tenerife, Canary Islands.…”
Section: Introductionmentioning
confidence: 99%