Interference caused by the contents of serum separator tubes in the Vitros CRP assay

Abstract: Background We have observed discrepancies between C-reactive protein (CRP) measured in serum prepared from a serum separator tube (SST) and that obtained from a plain tube, when using the Vitros CRP assay. Our study aimed at elucidating the cause of these discrepancies.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
8
1
1

Year Published

2010
2010
2021
2021

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 6 publications
1
8
1
1
Order By: Relevance
“…Therefore, these laboratories are vulnerable to occlusion of sample probes from inappropriately separated blood samples. The partial or complete obstruction of sample probes, gel aspiration and/or inadequate sample aspiration by laboratory instrumentation may affect test results, increase turn-around time, and the cost of analyses (4,5,7). …”
Section: Discussionmentioning
confidence: 99%
“…Therefore, these laboratories are vulnerable to occlusion of sample probes from inappropriately separated blood samples. The partial or complete obstruction of sample probes, gel aspiration and/or inadequate sample aspiration by laboratory instrumentation may affect test results, increase turn-around time, and the cost of analyses (4,5,7). …”
Section: Discussionmentioning
confidence: 99%
“…However, some limitations associated with gel tubes. One limitation was that the gel contained within serum separator tubes had the potential for adsorbing analytes of interest (8,9) or releasing material that may interfere with analytes (10). Another limitation of serum separator tubes was that certain analytes, such as therapeutic drugs and steroid hormones, may be instable when serum were stored on the barrier for long periods of time (2,3).…”
Section: Discussionmentioning
confidence: 99%
“…Also, analyte stability in serum separator tubes had been documented in the past (7,8). One disadvantage of gel separator tubes was that the gel contained within such tubes had the potential for adsorbing analytes of interest (9,10) or releasing material that may interfere with assay chemistries (11). Another disadvantage of gel separator tubes was the instability of certain analytes when serum was stored for long periods of time on the barrier (2,3), such as therapeutic drugs and steroid hormones.…”
Section: Discussionmentioning
confidence: 99%