2013
DOI: 10.1093/jrr/rrt125
|View full text |Cite
|
Sign up to set email alerts
|

Internal dosimetry estimates using voxelized reference phantoms for thyroid agents

Abstract: This work presents internal dosimetry estimates for diagnostic procedures performed for thyroid disorders by relevant radiopharmaceuticals. The organ doses for 131Iodine, 123Iodine and 99mTc incorporated into the body were calculated for the International Commission on Radiological Protection (ICRP) reference voxel phantoms using the Monte Carlo transport method. A comparison between different thyroid uptakes of iodine in the range of 0–55% was made, and the effect of various techniques for administration of 9… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 3 publications
(12 reference statements)
0
10
0
Order By: Relevance
“…This issue has been addressed earlier for the adult female ICRP voxel phantom [18]. Of particular importance is the fetal thyroid dose, which decreases by a factor of 15 as a result of increased maternal thyroid uptake.…”
Section: Resultsmentioning
confidence: 96%
“…This issue has been addressed earlier for the adult female ICRP voxel phantom [18]. Of particular importance is the fetal thyroid dose, which decreases by a factor of 15 as a result of increased maternal thyroid uptake.…”
Section: Resultsmentioning
confidence: 96%
“…The detailed discussion on the contributions to internal doses could be found in Refs. [17,18,37]. However, the higher dose to fetal skeleton is yet clear.…”
Section: B1 Ctpamentioning
confidence: 99%
“…used the stylized pregnant phantoms in dose estimation with three layers of 1.5 cm thickness mimic various body mass indexes . Several studies have been conducted to show the systematic discrepancy between data obtained with stylized phantom and image‐based computational phantoms . ICRP recommendations also confirm that external and internal dosimetry calculations should be performed using image‐based computational phantoms replacing the use of various stylized models .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In the previous paper, absorbed doses from 131 I and 123 I sodium iodide in voxel phantoms were calculated and compared with the values obtained for the corresponding stylized phantoms (Hoseinian-Azghadi et al, 2013). In this study, further details about the contributions of photons and electrons to organ doses from each source region are assessed and discussed for 131 I and 123 I.…”
Section: Mirihakim@ferdowsiumacirmentioning
confidence: 99%