2012
DOI: 10.1029/2011jc007613
|View full text |Cite
|
Sign up to set email alerts
|

Interpreting LISST‐100X measurements of particles with complex shape using digital in‐line holography

Abstract: [1] Measurements of suspended sediment volume concentrations, particle size and number density are routinely collected in marine and fresh-water environments with LISST-100X instruments to understand sediment transport, biological processes and fundamental opto-acoustic problems. A LISST-100X was simultaneously deployed with a novel holographic camera (holocam) in UK coastal waters to assess the performance of the laser diffraction technique when measuring natural suspensions. Volume distributions from the LIS… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
63
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 66 publications
(67 citation statements)
references
References 32 publications
4
63
0
Order By: Relevance
“…Particles smaller than the size range affect the entire PSD, with an increase in the volume concentration of the smallest two size classes, a decrease in the next size classes and, an increase in the largest size classes [40]. Similar remarks have been formulated by Graham and coworkers [41], who observed an overestimation of one or two orders of magnitude in the number of fine particles measured by the LISST. A rising tail in the lowest size classes of the LISST occurs regularly in the data during highly turbulent conditions and is interpreted as an indication of the presence of very fine particles and thus a break-up of the aggregates.…”
Section: Tidal Measurementssupporting
confidence: 60%
See 1 more Smart Citation
“…Particles smaller than the size range affect the entire PSD, with an increase in the volume concentration of the smallest two size classes, a decrease in the next size classes and, an increase in the largest size classes [40]. Similar remarks have been formulated by Graham and coworkers [41], who observed an overestimation of one or two orders of magnitude in the number of fine particles measured by the LISST. A rising tail in the lowest size classes of the LISST occurs regularly in the data during highly turbulent conditions and is interpreted as an indication of the presence of very fine particles and thus a break-up of the aggregates.…”
Section: Tidal Measurementssupporting
confidence: 60%
“…The occurrence of rising tail in the largest size classes indicates the occurrence of large particles rather than an absolute value. Other uncertainties of the LISST-100C are related to the often non-spherical shape of the particles occurring in nature [40,41,44]. A hull mounted, acoustic Doppler current profiler (ADCP) type, Workhorse Mariner 300 kHz (RD Instruments, Poway, CA, USA), was used to determine the velocity profiles.…”
Section: Tidal Measurementsmentioning
confidence: 99%
“…However, particles less than the smallest size class or bigger than the largest size class affect the measurements in the spectrum [42][43][44][45][46][47][48][49][50][51][52]. In this study, we followed the recommendation of former authors to remove the first and last classes for calculating the general slope of the particle size distribution and the mean apparent diameter D 50 [42][43][44][45][46][47][48][49][50][51][52]. Based on data between class #2 and class #31, D 50 was thus calculated as the diameter corresponding to 50% of the cumulative volume concentration of aggregates between 1.48 and 212 µm.…”
Section: Spm Volume Concentration (Spmvc) and Particle Size Distributmentioning
confidence: 99%
“…Drones are also equipped with multi-or hyperspectral sensors to map water colour and water quality parameters at high definition [289]. The potential of an instrument such as the LISST 100-X since its commercialization (about fifteen years) has not yet been encompassed that a second generation of instrument is available using holograms (LISST-HOLO, [290]), then a third generation (LISST-200X) to better measure larger particles and benefit from more robust optics. New sensors are regularly introduced, applied and compared to older ones: infrared laser turbidimeter adapted to very turbid water [291], comparison of acoustic and optical backscatter sensors in cohesive suspension [292,293], etc.…”
Section: A Science Field That Evolves With Technologymentioning