2018
DOI: 10.1021/acs.jpcb.8b07000
|View full text |Cite
|
Sign up to set email alerts
|

Interrogating the Osmotic Pressure of Self-Crowded Bovine Serum Albumin Solutions: Implications of Specific Monovalent Anion Effects Relative to the Hofmeister Series

Abstract: The free-solvent-based (FSB) model and osmotic pressure were used to probe the ion binding and protein hydration for self-crowded bovine serum albumin in 0.15 M NaF, NaCl, NaI, and NaSCN solutions. All experiments were conducted with solutions at pH 7.4. The regressed results of the FSB model behavior to the measured osmotic pressure were excellent, albeit, the osmotic pressure data for NaSCN were noisy. The resulting ion binding and hydration were realistic values and the covariance of the two parameters was … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
5
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 90 publications
0
5
0
Order By: Relevance
“…17 Yousef used a pressure transducer for the osmotic pressure measurements but the overall time for measurement equilibrium remained approximately 5-6 h. 17 Similar time requirements are reported in other studies where the osmotic pressure profile is generated. [18][19][20][21] Hale et al ( 2018) modified the osmometer further by increasing the volume of the solvent-side chamber of the device. This ultimately acted as an infinite sink and eliminated solution-side concentration corrections.…”
Section: Introductionmentioning
confidence: 99%
See 4 more Smart Citations
“…17 Yousef used a pressure transducer for the osmotic pressure measurements but the overall time for measurement equilibrium remained approximately 5-6 h. 17 Similar time requirements are reported in other studies where the osmotic pressure profile is generated. [18][19][20][21] Hale et al ( 2018) modified the osmometer further by increasing the volume of the solvent-side chamber of the device. This ultimately acted as an infinite sink and eliminated solution-side concentration corrections.…”
Section: Introductionmentioning
confidence: 99%
“…Nevertheless, excessive sample preparation time and material use were not eliminated. 21 Overall, a time commitment on the order of days is required to generate a single osmotic pressure profile.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations