1990
DOI: 10.1016/s0002-8703(05)80187-5
|View full text |Cite
|
Sign up to set email alerts
|

Interstudy reproducibility of dimensional and functional measurements between cine magnetic resonance studies in the morphologically abnormal left ventricle

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
97
1
2

Year Published

1996
1996
2010
2010

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 269 publications
(102 citation statements)
references
References 30 publications
2
97
1
2
Order By: Relevance
“…The Bland-Altman analysis revealed a good agreement between all CMR measurements computed for the manual and automatic planning methods. The limits of agreement for the automated CMR planning are comparable with previously published ones for interstudy variability (6,15,36,37). Additionally, the percentages of variability were low for all CMR measurements and amounted to 1.9 -4.5%.…”
Section: Discussionsupporting
confidence: 84%
See 2 more Smart Citations
“…The Bland-Altman analysis revealed a good agreement between all CMR measurements computed for the manual and automatic planning methods. The limits of agreement for the automated CMR planning are comparable with previously published ones for interstudy variability (6,15,36,37). Additionally, the percentages of variability were low for all CMR measurements and amounted to 1.9 -4.5%.…”
Section: Discussionsupporting
confidence: 84%
“…Errors in CMR measurements are due to positional, physiological, planning, and measuring factors that comprise the interstudy variability (1,3,5,12,15,36,37). All of the subjects remained inside the magnet bore during the examination, so positional variability (12) was minimized.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Images were obtained using a 3.5 MHz transducer, and images were acquired in standard apical and parasternal two-and four-chamber views. Two readers measured the chamber and wall dimensions using standard recommendations for chamber quantification in consensus [34]. LVEF was calculated using the modified Simpson's method [35,36].…”
Section: Two-dimensional Echocardiographymentioning
confidence: 99%
“…Global functional indices of the heart, e.g., myocardial mass, end-diastolic volume, end-systolic volume and ejection fraction, can be measured using CINE MRI [4][5][6][7]. Regional tissue viability can be assessed with perfusion MR, e.g., using arterial spin labeling techniques [8], or from the delayed enhancement effect following gadolinium diethylenetriamine penta-acetic acid (Gd-DTPA) injection [9].…”
Section: Introductionmentioning
confidence: 99%