Intraocular Pressure Monitoring Sensors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
44
0

Year Published

2009
2009
2021
2021

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 86 publications
(44 citation statements)
references
References 55 publications
0
44
0
Order By: Relevance
“…Passive telemetric sensing has been widely used as one of the viable methods to accomplish continuous and accurate non-contact IOP measurements of glaucoma patients [1,2]. It enables straightforward IOP sensing by utilizing a transensor implant that registers environmental pressure variations inside the eye, so that the IOP can be directly measured by using an external reader wirelessly interrogating the implant.…”
Section: Introductionmentioning
confidence: 99%
“…Passive telemetric sensing has been widely used as one of the viable methods to accomplish continuous and accurate non-contact IOP measurements of glaucoma patients [1,2]. It enables straightforward IOP sensing by utilizing a transensor implant that registers environmental pressure variations inside the eye, so that the IOP can be directly measured by using an external reader wirelessly interrogating the implant.…”
Section: Introductionmentioning
confidence: 99%
“…Telemetric sensing is one of the viable methods to accomplish continuous and faithful noncontact IOP measurements [5], [6]. It utilizes a transensor implant that registers environmental pressure variations inside the eye so that the IOP can be directly measured by using an external reader wirelessly interrogating the implant.…”
mentioning
confidence: 99%
“…However, despite successful wireless pressure sensing demonstration, the sensing distance of the entire sensor-reader system in the previous work was not sufficient in practice. Such challenge can also be found in other works with considering size and other constraints [6]. As a result of further improvement, this work focuses on a different sensor design for electromagnetic coil coupling and resonance quality factor enhancements, followed by a new readout method for noise reduction and signal-to-noise ratio (SNR) enhancement in actual wireless measurements [20].…”
mentioning
confidence: 99%
“…Such measurements can only be obtained for up to 24 h because of side complications that accompany long-term use [41][42][43] . To overcome the aforementioned limitations, implants based on radio-frequency (RF) technologies have been used to monitor endovascular pressure 44 , intracranial pressure (ICP) 45,46 , and IOP [47][48][49][50][51][52][53][54][55][56][57][58] . The typical size of these implants ranges from a millimeter to a few centimetres.…”
Section: Introductionmentioning
confidence: 99%