2010
DOI: 10.1080/10407790903508129
|View full text |Cite
|
Sign up to set email alerts
|

Inverse Identification of Thermal Properties of Charring Ablators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 34 publications
(6 citation statements)
references
References 29 publications
0
6
0
Order By: Relevance
“…In the general framework of flammability properties this approach has been seldom used [68,69] although it has recently received renewed attention [70][71][72][73][74][75][76]. Numerous similar efforts, though, exist in the literature mostly aimed at determining a limited set of thermal properties and for specific applications [77][78][79][80][81][82].…”
Section: Optimizationmentioning
confidence: 99%
See 1 more Smart Citation
“…In the general framework of flammability properties this approach has been seldom used [68,69] although it has recently received renewed attention [70][71][72][73][74][75][76]. Numerous similar efforts, though, exist in the literature mostly aimed at determining a limited set of thermal properties and for specific applications [77][78][79][80][81][82].…”
Section: Optimizationmentioning
confidence: 99%
“…As can be expected, the optimization problem is complex and highly non-linear. Therefore, local search methods such as direct search [83] and gradient search [84] algorithms are not applicable; however, such methods have been used widely for property estimation [68,69,77,81,82]. Global methods are needed which can tackle the major complications of high-dimensionality optimization such as local optima, multiple attraction basins, discontinuities, etc.…”
Section: Optimizationmentioning
confidence: 99%
“…The initial concept of employing the 950 nm wavelength to monitor bladder volume was proposed by Macnab and then validated by Molavi et al, 23 first in vitro using a specially constructed phantom incorporating a fillable latex balloon to simulate the bladder, and then with an in vivo voiding study. The experimental NIRS prototype used a 950 nm LED (55 nm spectral half-width, 16 mw nominal power) driven by a constant current driver and a 5.22 mm silicone photodiode detector integrated with a transimpedance amplifier.…”
Section: Discussionmentioning
confidence: 99%
“…However, high-frequency measurements noise significantly affect the quality of the results obtained with the inverse method. When the unknown parameters are constant (time and space), the adjoint functions are not necessary and the minimization may be performed with the sensitivity functions which simplifies the method [11][12][13][14].…”
Section: Introductionmentioning
confidence: 99%