2018
DOI: 10.1109/access.2018.2804046
|View full text |Cite
|
Sign up to set email alerts
|

Investigating Particularities of Infeed and Fault Resistance Effect on Distance Relays Protecting Radial Distribution Feeders With DG

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
15
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 39 publications
(15 citation statements)
references
References 14 publications
0
15
0
Order By: Relevance
“…However, distance relays face difficulties in power distribution systems with short lines, dynamically changing in-feeds from installed PV systems and substantially unbalanced lines. Some of the challenges of application of distance protection for power distribution systems are discussed in [46]. The directional over-current relay with adaptive settings is another possible approach [47].…”
Section: E Impact On Existing Protection Schemesmentioning
confidence: 99%
“…However, distance relays face difficulties in power distribution systems with short lines, dynamically changing in-feeds from installed PV systems and substantially unbalanced lines. Some of the challenges of application of distance protection for power distribution systems are discussed in [46]. The directional over-current relay with adaptive settings is another possible approach [47].…”
Section: E Impact On Existing Protection Schemesmentioning
confidence: 99%
“…Many other researchers propose extending out the distance relay reach in the distribution network with the distributed generation, as well as applying the distance protection scheme in a mixed distribution network with DG (Nikolaidis et al 2018). The author has investigated the aspect of DG contribution and the deviation in resistance measurement in radial distribution feeders with DG.…”
Section: Related Workmentioning
confidence: 99%
“…On the other hand, the second strategies focus on improving the protection systems to cope with the protection problems related to DG integration in the micro‐grids. In this regard, different measures are proposed consist of applying fault current limiters (FCLs) to improve the DG's fault ride‐through (FRT) capability, 9,10 using the new and programmable protection devices, 11‐13 proposing different protection schemes based on distance, differential or directional relays, 14‐18 and applying the communication systems for improving the performance of the protection systems 19,20 . While the first strategies can solve the protection issues, it may bring adverse impacts on the performance of the power system.…”
Section: Introductionmentioning
confidence: 99%
“…Another classification of protection coordination methods of active distribution systems is presented in Table 1. According to Table 1, both DG‐based and the protection system (PS)‐based strategies can be implemented in an offline 15,22‐24 or online 8,25‐30 manner. In the offline methods, the coordination of protection devices is ensured in sizing and siting of DGs in the planning stage 6,31‐33 or output of DGs in operation stage 8,34‐36 .…”
Section: Introductionmentioning
confidence: 99%