2018
DOI: 10.14710/ijred.7.3.223-231
|View full text |Cite
|
Sign up to set email alerts
|

Investigating the effect of DG infeed on the effective cover of distance protection scheme in mixed-MV distribution network

Abstract: The environmental and economic features of renewable energy sources have made it possible to be integrated as Distributed Generation (DG) units in distribution networks and to be widely utilized in modern distribution systems. The intermittent nature of renewable energy sources, altering operational conditions, and the complex topology of active distribution networks makes the level of fault currents significantly variable. Thus, the use of distance protection scheme instead of conventional overcurrent schemes… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 27 publications
(28 reference statements)
0
2
0
Order By: Relevance
“…The new technique for online tracking of fault location in distribution networks was introduced in Ahmed et al (2021) to enhance system reliability and continuity of supply. Based on two-end measurements, Christos et al (2022) proposed the two formulations of fault location algorithm which was appropriate for unbalanced medium voltage overhead distribution systems of radial network with or without distributed generations (Khoa, Van, Hung and Tuan, 2022;Saad et al 2018). The fault location algorithm based on synchronous phasor measurement for shunt-compensated lines under dynamic conditions was proposed to overcome the uncertainties in the controller parameters of the shunt compensator device (Deng et al 2022;Khoa et al 2017).…”
Section: Notificationmentioning
confidence: 99%
“…The new technique for online tracking of fault location in distribution networks was introduced in Ahmed et al (2021) to enhance system reliability and continuity of supply. Based on two-end measurements, Christos et al (2022) proposed the two formulations of fault location algorithm which was appropriate for unbalanced medium voltage overhead distribution systems of radial network with or without distributed generations (Khoa, Van, Hung and Tuan, 2022;Saad et al 2018). The fault location algorithm based on synchronous phasor measurement for shunt-compensated lines under dynamic conditions was proposed to overcome the uncertainties in the controller parameters of the shunt compensator device (Deng et al 2022;Khoa et al 2017).…”
Section: Notificationmentioning
confidence: 99%
“…Several methods have been developed to locate the fault in transmission and distribution lines [7][8][9][10][11]. The method based on reactance measurement has been proposed to locate a fault on overhead transmission lines of alternating current electrified railway [12].…”
Section: Introductionmentioning
confidence: 99%