2018
DOI: 10.1016/j.applthermaleng.2018.03.015
|View full text |Cite
|
Sign up to set email alerts
|

Investigation in performance of a hybrid under-floor air distribution with improved desk displacement ventilation system in a small office

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(6 citation statements)
references
References 44 publications
0
6
0
Order By: Relevance
“…Authors do not promote any commercial CFD package, and encourage diverse application of CFD in PV studies, including the open-source OpenFOAM, which has powerful grid capabilities and a wide range of applications [126]. Note that Airpak is no longer updated, but it has been used in recent studies [123].…”
Section: Yearly Publication Distributionmentioning
confidence: 99%
See 2 more Smart Citations
“…Authors do not promote any commercial CFD package, and encourage diverse application of CFD in PV studies, including the open-source OpenFOAM, which has powerful grid capabilities and a wide range of applications [126]. Note that Airpak is no longer updated, but it has been used in recent studies [123].…”
Section: Yearly Publication Distributionmentioning
confidence: 99%
“…To assess the influence of a PV system on thermal comfort, mean skin surface temperature, as an important factor influencing a human's thermal sensation, was employed by calculating Fanger's thermal comfort model parameters and by considering the heat generation and balance for a sleeping person [109,110]. Finally, the commonly used comfort indices-e.g., predicted mean vote (PMV) and predicated percentage of dissatisfaction (PPD), as well as the improvement of overall thermal sensation (DPMV) [107]-were used to examine an occupant's thermal comfort [123]. The impact of PV on CTM thermal comfort is mostly evaluated using the ATC model.…”
Section: Thermal Comfortmentioning
confidence: 99%
See 1 more Smart Citation
“…The first mode concerns detailed indoor airflow modelling with simplified thermal boundary conditions imposed on the room envelope (eg. walls are at a constant temperature [ 18 ], or adiabatic in nature [ 11 ]). Here, the possible impact of heat transfer across the envelope in terms of changes in the indoor airflow cannot be identified.…”
Section: Introductionmentioning
confidence: 99%
“…The convective and radiative transfer heat from non-airconditioned zone to air-conditioning zone were calculated as an additional cooling load in the lower air-conditioning zone [1][2][3] This method has been widely used for calculating the cooling load of large space buildings. Kang Zhao [4] proposed a new method to calculated the cooling capacity of a radiant floor in the large spaces of an airport, In addition, the theoretical research on stratified airconditioning load in the lower air supply distribution were focused on the stratified height [5], the load efficiency coefficient [6], the lower air supply load correction factor [7], the supply and return air heights, the indoor heat source distribution [8] and outdoor disturbances affect the stratified load.…”
Section: Introductionmentioning