Investigation of applicability of alanine and radiochromic detectors to dosimetry of proton clinical beams

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
18
0

Year Published

2002
2002
2020
2020

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 36 publications
(18 citation statements)
references
References 10 publications
0
18
0
Order By: Relevance
“…However, the lack of standards guidance and concern over recombination in high fluence rate particle beams prompted additional absolute dosimetry comparisons. Therefore, two additional methods were used for this work: alanine dosimetry pellets 25,26 and thermoluminescent dosimetry. Nine alanine dosimetry pellets produced by Far West Technologies and having a NIST-traceable calibration were obtained from Armed Forces Radiobiological Research Institute ͑AFRRI͒ and irradiated in the reference field, at the center of SOBP, to a dose of 250 Gy.…”
Section: Iib2 Absolute Dosimetrymentioning
confidence: 99%
“…However, the lack of standards guidance and concern over recombination in high fluence rate particle beams prompted additional absolute dosimetry comparisons. Therefore, two additional methods were used for this work: alanine dosimetry pellets 25,26 and thermoluminescent dosimetry. Nine alanine dosimetry pellets produced by Far West Technologies and having a NIST-traceable calibration were obtained from Armed Forces Radiobiological Research Institute ͑AFRRI͒ and irradiated in the reference field, at the center of SOBP, to a dose of 250 Gy.…”
Section: Iib2 Absolute Dosimetrymentioning
confidence: 99%
“…Most of the systems in use are based on single or arrays of ionization chambers and on films, which are certainly precise but suffer for lengthy procedures. Nichiporov et al 4 examined the usefulness of multichannel detectors, while in many other studies [5][6][7][8][9] , film dosimetry has been proposed to verify dose distributions and perform QA in proton therapy. Film dosimetry, shown to be highly precise, does not give immediate results because the procedures required for preparing, scanning, calibration, and off-line analysis are time-consuming.…”
Section: Introductionmentioning
confidence: 99%
“…Other dosimetric systems such as radiochromic films, 72,73 alanine detectors, 73 and polymer gels 74 can be used for QA measurements. However, the use of these systems is limited because of saturation effects in the proton stopping region and because they are not real-time instruments.…”
Section: Ivc7 Qa Systems For Scanned Proton Beamsmentioning
confidence: 99%