2005
DOI: 10.1016/j.susc.2004.04.062
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of carboxylic-functionalized and n-alkanethiol self-assembled monolayers on gold and their application as pH-sensitive probes using scanning electrochemical microscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
37
0
1

Year Published

2007
2007
2014
2014

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 31 publications
(38 citation statements)
references
References 47 publications
0
37
0
1
Order By: Relevance
“…[260] Die SECM erwies sich weiterhin als geeignet, die durch Kettenlänge, Protonierungs-oder Komplexbildungsgleichgewichte veränderten Eigenschaften von terminal funktionalisierten SAMs zu differenzieren. [261,262] Ebenfalls untersucht wurde die ¾nderung des Passivierungsverhaltens von DNA-haltigen SAMs bei der Bindung von zweiwertigen Kationen. [263] Zu erwähnen ist auch der Ansatz von Abbou et al zur Charakterisierung von Polymerketten, die an einem Ende an einer Oberfläche verankert und am anderen Ende mit einer Ferroceneinheit markiert sind.…”
Section: Untersuchung Selbstorganisierter Monolagenunclassified
“…[260] Die SECM erwies sich weiterhin als geeignet, die durch Kettenlänge, Protonierungs-oder Komplexbildungsgleichgewichte veränderten Eigenschaften von terminal funktionalisierten SAMs zu differenzieren. [261,262] Ebenfalls untersucht wurde die ¾nderung des Passivierungsverhaltens von DNA-haltigen SAMs bei der Bindung von zweiwertigen Kationen. [263] Zu erwähnen ist auch der Ansatz von Abbou et al zur Charakterisierung von Polymerketten, die an einem Ende an einer Oberfläche verankert und am anderen Ende mit einer Ferroceneinheit markiert sind.…”
Section: Untersuchung Selbstorganisierter Monolagenunclassified
“…[14][15][16][17][18] The procedure was as follows: The Au/mica electrode was annealed using a hydrogen flame and immersed for 5 min without potential control into 20 mM 4, 4 0 -dithiodipyridine aqueous solution, which was deaerated to prevent the oxidation of thiol. The electrode was thoroughly rinsed with water, and then used as a 4, 4 0 -dithiodipyridine-modified self-assembled-monolayer (4-PyS-SAM) working electrode.…”
Section: Experimental Procedures 1 Materials and Solutionsmentioning
confidence: 99%
“…The electrode potential sweep was set for the 4-PyS-SAM from +0.2 to À0:2 V vs. Ag/AgCl in order to avoid the reductive desorption of 4-PyS-SAM, 16) and was regulated for Alk-SAM from +0.2 V to À0:4 V vs. Ag/AgCl. 18) We measured the reductive elimination of each SAM by the reduction of thiol in the SAMs and found that the surface coverage of these SAMs were 4:75 Â 10 À10 , 7:21 Â 10 À10 , 7:52 Â 10 À10 , and 7:83 Â 10 À10 mol cm À2 for 4-PyS-SAM, COOH-, OH-, and NH 2 -Alk-SAM, respectively. The surface coverage obtained for the SAMs was nearly the same as that shown in the literature.…”
Section: Electrochemical Measurement Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…Depending on the potential applied to the electrode, the feedback current can be attributed to direct electron tunneling or ET through pinholes. SECM approach curves with use of different redox mediators show that the insulating properties increase with increasing chain length of the SAM-forming molecule [260]. By use of nanometersized electrodes it was shown that direct electron transfer through the layer, rather than electron transfer at the defects, was dominant and that the size of the defects was 1-100 nm [261].…”
Section: Self Assembled Monolayersmentioning
confidence: 99%