2015
DOI: 10.12989/sss.2015.15.2.447
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of mode identifiability of a cable-stayed bridge: comparison from ambient vibration responses and from typhoon-induced dynamic responses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
8
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 36 publications
(15 citation statements)
references
References 29 publications
1
8
0
Order By: Relevance
“…Therefore, they are expelled from the identification. The identified results from non-blind data are comparable to results reported in a previous study(Ni et al 2015), i.e. the second mode (0.23 Hz) is not identified under weak wind conditions.…”
supporting
confidence: 84%
See 2 more Smart Citations
“…Therefore, they are expelled from the identification. The identified results from non-blind data are comparable to results reported in a previous study(Ni et al 2015), i.e. the second mode (0.23 Hz) is not identified under weak wind conditions.…”
supporting
confidence: 84%
“…Data from Sample 7 to Sample 10 were measured under typhoon conditions. Data from Sample 11 to Sample 13 were measured at wind speeds around the critical value (threshold) of 7.5 m/s, at which the deficient mode becomes identifiable (Ni et al 2015). Traffic was blocked during the typhoons.…”
Section: Benchmark Datamentioning
confidence: 99%
See 1 more Smart Citation
“…Then, 8 longitudinal stabilizing cables used to diagonally connect the top of the central tower to the Ting Kau and Tsing Yi towers, whose length reaches 465m, are installed. Whereas, 64 cables are employed to strengthen the three towers in the lateral direction (Ni et al 2015). Within a long-term structural health monitoring system conceived by the Hong Kong SAR Government Highways Department, during the construction of the bridge and also after its completion in 1999 (Wong 2004;Ko and Ni 2005), more than 230 sensors have been placed on the TKB.…”
Section: Figure 2 General Layout Of the Ting Kau Bridgementioning
confidence: 99%
“…Moreover, when typhoon condition are considered, significant variations in the stay-cables can be observed. A benchmark problem on an existing cable-stayed bridge was recently proposed and it focused on the modal identification (Ni et al 2015;Casciati et al 2015). Particularly, during a typhoon, some frequencies that during service conditions are not detected, were excited.…”
Section: Introductionmentioning
confidence: 99%