2015
DOI: 10.1007/s10877-015-9761-0
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of peripheral photoplethysmographic morphology changes induced during a hand-elevation study

Abstract: This is the accepted version of the paper.This version of the publication may differ from the final published version. Abstract A hand-elevation study was carried out in the laboratory in order to alter peripheral blood flow with the aim of increasing understanding of factors affecting the morphology of peripheral photoplethysmographic signals. Photoplethysmographic (PPG) signals were recorded from twenty healthy volunteer subjects during a hand-elevation study in which the right hand was raised and lowered re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
37
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 40 publications
(37 citation statements)
references
References 36 publications
0
37
0
Order By: Relevance
“…However, due to the complexity of the PPG signal and the diversity of usage scenarios for wearable health devices, PPG signal processing is confronted by issues of strong interference and high noise. Researchers 16 , 26 , 27 have carried out a number of studies in this area, verifying that morphological information obtained from PPGs change when different signal-acquisition processes are used. However, there are no comparative studies that examine what the optimal filtering method for PPG signals is.…”
Section: Discussionmentioning
confidence: 92%
“…However, due to the complexity of the PPG signal and the diversity of usage scenarios for wearable health devices, PPG signal processing is confronted by issues of strong interference and high noise. Researchers 16 , 26 , 27 have carried out a number of studies in this area, verifying that morphological information obtained from PPGs change when different signal-acquisition processes are used. However, there are no comparative studies that examine what the optimal filtering method for PPG signals is.…”
Section: Discussionmentioning
confidence: 92%
“…These results can be explained by increased blood vessel resistance shown in pulse area change or decreased maximum blood volume due to vasoconstriction. From a similar viewpoint, significant increase in L sys indicates that contracted vessels might have increased the vascular resistance due to vasoconstriction of the sympathetic nerves (Jaryal et al, 2009; Hickey et al, 2016). TriA, TriA sys , and TriA dia in the area of a triangle where the waveform of the high frequency component such as harmonics was removed showed similar patterns as those of A, A sys , and A dia , respectively.…”
Section: Discussionmentioning
confidence: 99%
“…However, it is well documented that this slowly varying component is a carrier of valuable physiological information [ 8 10 ] and changes in DC PPG during occlusion of the venous circulation have been reported firstly by Hertzman and Dillon [ 19 ], and later by Almond et al [ 20 ]. Also, there is a growing interest in extracting new information from the PPG signal such as pulsatile pressure, venous oxygenation, or features of the PPG signal that could identify any other haemodynamic parameter different from SpO [ 21 24 ]. This paper investigates further the feasibility of estimating relative changes in the concentration of oxygenated, reduced, and total haemoglobin from the DC component of the PPGs acquired from a custom-made, dual-wavelength reflectance sensor.…”
Section: Discussionmentioning
confidence: 99%