2021
DOI: 10.1007/s10800-021-01549-x
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of the effect of metallization ratio and side shift on the interdigitated electrodes performance for biochemical sensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 24 publications
1
4
0
Order By: Relevance
“…In our work, we summarized the measured C 0 versus η with different P in figure 5(c). It is clear C 0 with different P shows great distinction: the raising rate of C 0 remarkably slows down with increasing P. Furthermore, FEM is utilized to simulate C 0 with different P and η in figure 5(d) [28,29]. It can be seen that C 0 with different P demonstrate different increasing trends versus η, which is consistent with the measured results shown in the overlap figure in figure 5(e).…”
Section: Resultssupporting
confidence: 79%
See 1 more Smart Citation
“…In our work, we summarized the measured C 0 versus η with different P in figure 5(c). It is clear C 0 with different P shows great distinction: the raising rate of C 0 remarkably slows down with increasing P. Furthermore, FEM is utilized to simulate C 0 with different P and η in figure 5(d) [28,29]. It can be seen that C 0 with different P demonstrate different increasing trends versus η, which is consistent with the measured results shown in the overlap figure in figure 5(e).…”
Section: Resultssupporting
confidence: 79%
“…It is clear in the equations ( 3)-( 5) that the independent variable k is only related to η, and the capacitance C 0 calculated by the numerical method as a function of η is shown on the left of figure 5(f) [28][29][30]. For 0 < η < 0.2, C 0 has a slight rise, then it turns a nearly linear increase at 0.2 < η < 0.8.…”
Section: Resultsmentioning
confidence: 98%
“…1f) and total electric energy of 4.4 x 10 -9 J (Fig. 1g) are detected at the WE, which influences the output response of the fabricated device [21].…”
Section: A Comsol Simulationmentioning
confidence: 95%
“…The COMSOL Multiphysics model used in this study was built in a 3D structural mechanics module. Based on the study in reference [ 20 ], the metal ratio (a/p) was determined to be 50%. The gap length between the IDT and the reflectors was set to the width of one finger by default.…”
Section: Theory and Simulationmentioning
confidence: 99%