1995
DOI: 10.1016/0956-5663(95)96956-y
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of the effects of polar organic solvents on the activity of tyrosinase entrapped in a poly(ester-sulphonic acid) polymer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
16
0
1

Year Published

1997
1997
2009
2009

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 34 publications
(19 citation statements)
references
References 16 publications
2
16
0
1
Order By: Relevance
“…Several aspects of these data are noteworthy. First, the SPEs coated with AQ polymer with the procedure reported by Iwuoha [17] lost approximately 40% of the initial catechol sensitivity after aging at 65 ЊC for 2 weeks. Because Gibson et al reported that a combination of sugar alcohols and zinc ions stabilized several other enzymes, lactitol and zinc ions were added to the AQ-tyrosinase solution.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Several aspects of these data are noteworthy. First, the SPEs coated with AQ polymer with the procedure reported by Iwuoha [17] lost approximately 40% of the initial catechol sensitivity after aging at 65 ЊC for 2 weeks. Because Gibson et al reported that a combination of sugar alcohols and zinc ions stabilized several other enzymes, lactitol and zinc ions were added to the AQ-tyrosinase solution.…”
Section: Resultsmentioning
confidence: 99%
“…In addition, the electrodes produced by Kottee et al are not sufficiently stable for commercial applications. Iwuoha, Adeyoju, Dempsey, Liu, and Wang [17] showed that tyrosinase could be immobilized in an ionomer film on the surface of an electrode by a simple inexpensive casting process, but did not apply this process to mass-producible electrodes, nor demonstrate stability sufficient for commercial applications. Recently, Wang [18] demonstrated that inexpensive biosensors for phenolic compounds could be produced by screen-printing a mixture of graphite and tyrosinase in a single step.…”
Section: Contract Grant Sponsor: U S Environmental Protection Agencmentioning
confidence: 99%
See 1 more Smart Citation
“…To probe if the biosensor response follows Michaelis -Menten kinetics, the Hill coefficient, n, was calculated [16]. The n values for all biosensors were quite higher than unity, indicating a deviation from Michaelis-Menten kinetics, probably due to the difficulty of the substrate to diffuse through the polymeric matrix, so, catalytic constants could not be calculated.…”
Section: à2mentioning
confidence: 99%
“…Diferentes sistemas bioanalíticos basados en enzimas han sido desarrollados para ser usados en medios orgánicos, generalmente electrodos enzimáticos (87,88 La idea de que las enzimas pueden retener su actividad en una amplia variedad de medios orgánicos está actualmente aceptada (93)(94)(95). Sin embargo, en todos los casos mencionados, las enzimas permanecen activas en función de la fina capa de agua que las rodea y estabiliza.…”
Section: Inmunoensayos Y Medios Orgánicosunclassified