2017
DOI: 10.1080/14733315.2017.1392107
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of the number of particles in an operating room at different ambient temperatures and inlet velocities

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0
2

Year Published

2018
2018
2022
2022

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 18 publications
0
5
0
2
Order By: Relevance
“…The application of CFD for investigating indoor air quality in operating rooms has been reported in some pieces of research. Accordingly, the ow characteristics in an operating room depend on its geometry and door opening cycles [25], ambient temperature [26], supply inlets and return outlets con guration [27], inlet di users geometry [28], ventilation air ow rate [29], location of obstacles [30], surgeons posture [31], sta clothing [32], and their activity level [33]. The results of previous studies showed that the location of return outlets was not as important as the location of supply inlets [34,35].…”
Section: Introductionmentioning
confidence: 99%
“…The application of CFD for investigating indoor air quality in operating rooms has been reported in some pieces of research. Accordingly, the ow characteristics in an operating room depend on its geometry and door opening cycles [25], ambient temperature [26], supply inlets and return outlets con guration [27], inlet di users geometry [28], ventilation air ow rate [29], location of obstacles [30], surgeons posture [31], sta clothing [32], and their activity level [33]. The results of previous studies showed that the location of return outlets was not as important as the location of supply inlets [34,35].…”
Section: Introductionmentioning
confidence: 99%
“…Of the 86 total articles investigating OR ventilation, 30 used modeling approaches to investigate the effects of HVAC components on the built environment. 31,41,[128][129][130][131][132][133][134][135][136][137]64,[138][139][140][141][142][143][144][145][146][147][121][122][123][124][125][126][127] Twenty-seven of those 30 articles utilized computational fluid dynamics (CFD) modeling. The numerical parameters in CFD models are often validated to some degree via small-scale or simplified experimental setups, or using previously published measurements.…”
Section: Modeling Studiesmentioning
confidence: 99%
“…Six of these studied inlet airflow velocity's effects on contamination, particle count, and particle deposition, but did not come to a consensus on an optimal inlet air velocity value. 31,123,125,126,133,134 One article concluded that contamination was minimized at a velocity of 2.37 m/s, but cautioned that airflow can easily be disrupted by slight changes in the design of the OR air curtain and exhaust vents 124 . The last article studied inlet airflow and its impact on airflow patterns.…”
Section: Modeling Studiesmentioning
confidence: 99%
“…This model was developed using renormalization. K-epsilon (k-ε) turbulence model is the most common model used in CFD to simulate mean flow characteristics for turbulence flow conditions [14,15]. Conservation of mass equation:…”
Section: Numerical Modelmentioning
confidence: 99%